Background And Objectives: An abnormal anion gap and an increased total protein and globulin are clues to the diagnosis of monoclonal gammopathy. We explored the utility of these markers in IgG, IgA, IgM, and free light chain monoclonal gammopathies.

Design, Setting, Participants, & Measurements: The anion gap, Na(+) - (Cl(-) + HCO(3)(-)), corrected for hypoalbuminemia, was calculated in patients with monoclonal gammopathies. Exclusion criteria were serum calcium >10.5 mg/dl and/or creatinine >2 mg/dl.

Results: Among 287 patients, 242 remained after applying exclusion criteria (109 IgG, 64 IgA, 21 IgM, and 48 light chain); 36% of 242 patients required correction for hypoalbuminemia. The anion gap was decreased (<10) in 22% of IgG and increased (>15) in 31% of IgA monoclonal gammopathies. IgM did not affect the gap. In light chain gammopathies, the anion gap showed no consistent trend (15% increased, 17% decreased). Mean clonal IgG, IgA, and IgM concentrations were 10-fold higher than mean clonal free light chain concentrations in the respective monoclonal gammopathies (P < 0.001). These paraprotein level disparities were reflected in significantly increased mean serum total protein and globulin concentrations in IgG, IgA, and IgM versus free light chain monoclonal gammopathies, where mean total protein and globulin levels were within normal limits (P < 0.001).

Conclusions: The anion gap was significantly altered in IgG and IgA monoclonal gammopathies, but it was not a sensitive tool for suspecting the diagnosis. In light chain monoclonal gammopathies, the anion gap, total protein, and globulin did not provide reliable diagnostic clues.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3255378PMC
http://dx.doi.org/10.2215/CJN.07380711DOI Listing

Publication Analysis

Top Keywords

anion gap
28
monoclonal gammopathies
28
light chain
24
igg iga
20
total protein
16
protein globulin
16
iga igm
16
free light
12
chain monoclonal
12
monoclonal
9

Similar Publications

Alkaline Hydrogen Evolution Reaction Electrocatalysts for Anion Exchange Membrane Water Electrolyzers: Progress and Perspective.

JACS Au

December 2024

Shanghai Key Laboratory for R&D and Application of Metallic Functional Materials, Institute of New Energy for Vehicles, School of Materials Science and Engineering, Tongji University, 201804, Shanghai, China.

For the aim of achieving the carbon-free energy scenario, green hydrogen (H) with non-CO emission and high energy density is regarded as a potential alternative to traditional fossil fuels. Over the last decades, significant breakthroughs have been realized on the alkaline hydrogen evolution reaction (HER), which is a fundamental advancement and efficient process to generate high-purity H in the laboratory. Based on this, the development of the practical industry-oriented anion exchange membrane water electrolyzer (AEMWE) is on the rise, showing competitiveness with the incumbent megawatt-scale H production technologies.

View Article and Find Full Text PDF

Background/objective: Diabetic ketoacidosis (DKA) is typically but not exclusively seen in patients with a history of diabetes mellitus.

Case Report: This is a case of 39 year-old male who was diagnosed with acute pancreatitis based on characteristic symptoms and positive CT findings on presentation. Laboratory testing revealed elevated serum glucose 251 mg/dL, low serum bicarbonate 8 mmol/L, increased anion gap 21, and elevated serum beta-hydroxybutyrate 9.

View Article and Find Full Text PDF

Anion modulation enhances the internal electric field of CuCoO to improve the catalysis in ammonia borane hydrolysis.

J Colloid Interface Sci

December 2024

School of Materials Science and Engineering, Tianjin Key Laboratory of Materials Laminating Fabrication and Interface Control Technology, Hebei University of Technology, Tianjin 300130, China. Electronic address:

Ammonia borane (NHBH, AB) is considered a promising chemical hydrogen storage material. The development of efficient, stable, and economical catalysts for AB hydrolysis is essential for realizing the hydrogen energy economy. In this study, a series of p-p heterojunction catalysts, labeled M (P/S/Cl)-CuCoO, were fabricated using the high-temperature vapor phase method to achieve anionic interface gradient doping.

View Article and Find Full Text PDF

Association between anion gap/calcium ratio and 30-day all-cause mortality in sepsis patients with diabetes mellitus.

Sci Rep

December 2024

Department of Endocrinology and Metabolism, Chengdu First People's Hospital, No.18 North Vientiane Road, High-Tech Zone, Chengdu, 610000, Sichuan, China.

We aimed to determine the association between anion gap-to-calcium ratio (ACR) and 30-day mortality in sepsis patients with diabetes mellitus (DM). Data for sepsis patients diagnosed with DM was extracted from Medical Information Mart for Intensive Care Database IV. After screening, 4429 eligible subjects were included in our study finally.

View Article and Find Full Text PDF

Background: The 15° left tilt position during caesarean delivery has been recommended by guidelines for many years, but recent studies have questioned the clinical benefit of left tilt position. We hypothesize that using a higher starting dose of metaraminol in the supine position will result in a non-inferior umbilical arterial pH, compared to the 15° left tilt position.

Methods: Healthy women undergoing elective caesarean delivery were randomized to the supine position (n = 62) or 15° left tilt position (n = 62) after spinal anaesthesia (0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!