Intraoperative esophageal Doppler hemodynamic monitoring in free perforator flap surgery.

Ann Plast Surg

St Andrew's Centre for Plastic Surgery and Burns, Broomfield Hospital, Chelmsford, United Kingdom.

Published: March 2013

Goal-directed fluid therapy optimizes cardiac output and flap perfusion during anesthesia. Intraoperative esophageal Doppler (ED) monitoring has been reported as more accurate and reliable, demonstrating improved surgical outcomes compared with central venous pressure and arterial catheter monitoring. A prospective study of patients undergoing free perforator (deep inferior epigastric artery perforator/anterolateral thigh) flap surgery with intraoperative ED monitoring (51 patients) or central venous pressure monitoring (53 patients) was undertaken. Fluid input included crystalloids, colloids, or blood products. Fluid output included urine, blood, or suctioned fluid. Postoperative fluid balance was calculated as fluid input - output. Fluid input between groups was not different. Fluid output was greater in the ED group (P = 0.008). The ED group showed less fluid balance (P = 0.023), less anesthetic time (P = 0.001), less hospital stay (mean 1.9 days; P = 0.147), less monitoring and flap complications (P = 0.062). ED monitoring demonstrated no monitoring complications, provides a favorable postoperative fluid balance, and may reduce flap complications and hospital stay.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SAP.0b013e3182306005DOI Listing

Publication Analysis

Top Keywords

fluid input
12
fluid balance
12
fluid
10
intraoperative esophageal
8
esophageal doppler
8
monitoring
8
free perforator
8
flap surgery
8
central venous
8
venous pressure
8

Similar Publications

Machine Learning-Guided Fluid Resuscitation for Acute Pancreatitis Improves Outcomes.

Clin Transl Gastroenterol

January 2025

Division of Gastroenterology, Department of Medicine.

Objectives: Ariel Dynamic Acute Pancreatitis Tracker (ADAPT) is an artificial intelligence tool using mathematical algorithms to predict severity and manage fluid resuscitation needs based on the physiologic parameters of individual patients. Our aim was to assess whether adherence to ADAPT fluid recommendations versus standard management impacted clinical outcomes in a large prospective cohort.

Method: We analyzed patients consecutively admitted to the Los Angeles General Medical Center between June 2015 to November 2022 whose course was richly characterized by capturing more than 100 clinical variables.

View Article and Find Full Text PDF

Packed columns are commonly used in post-combustion processes to capture CO emissions by providing enhanced contact area between a CO-laden gas and CO-absorbing solvent. To study and optimize solvent-based post-combustion carbon capture systems (CCSs), computational fluid dynamics (CFD) can be used to model the liquid-gas countercurrent flow hydrodynamics in these columns and derive key determinants of CO-capture efficiency. However, the large design space of these systems hinders the application of CFD for design optimization due to its high computational cost.

View Article and Find Full Text PDF

Purpose: Predicting long-term anatomical responses in neovascular age-related macular degeneration (nAMD) patients is critical for patient-specific management. This study validates a generative deep learning (DL) model to predict 12-month posttreatment optical coherence tomography (OCT) images and evaluates the impact of incorporating clinical data on predictive performance.

Methods: A total of 533 eyes from 513 treatment-naïve nAMD patients were analyzed.

View Article and Find Full Text PDF

Mechanical force attracts booming attention with the potential to tune the tumor cell behavior, especially in cell migration. However, the current approach for introducing mechanical input is difficult to apply in vivo. How the mechanical force affects cell behavior in situ also remains unclear.

View Article and Find Full Text PDF

Protecting monoclonal antibodies via competitive interfacial adsorption of nonionic surfactants.

J Colloid Interface Sci

December 2024

Biological Physics Laboratory, Department of Physics and Astronomy, University of Manchester, Oxford Road, Schuster Building, Manchester M13 9PL, UK. Electronic address:

Hypothesis: Bioengineered monoclonal antibodies (mAbs) have gained significant recognition as medical therapies. However, during processing, storage and use, mAbs are susceptible to interfacial adsorption and desorption, leading to structural deformation and aggregation, and undermining their bioactivity. To suppress antibody surface adsorption, nonionic surfactants are commonly used in formulation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!