Endothelial cells constitute the natural inner lining of blood vessels and possess anti-thrombogenic properties. This characteristic is frequently used by seeding endothelial cells on vascular prostheses. As the type of anchorage of adhesion ligands to materials surfaces is known to determine the mechanical balance of adherent cells, we investigated herein the behaviour of endothelial cells under physiological shear stress conditions. The adhesion ligand fibronectin was anchored to polymer surfaces of four physicochemical characteristics exhibiting covalent and non-covalent attachment as well as high and low hydrophobicity. The in situ analysis combined with cell tracking of shear stress-induced effects on cultured isolated cells and monolayers under venous (0.5 dyn/cm(2)) and arterial (12 dyn/cm(2)) shear stress over a time period of 24 h revealed distinct differences in their morphological and migratory features. Most pronounced, unidirectional and bimodal migration patterns of endothelial cells in or against flow direction were found in dependence on the type of substrate-matrix anchorage. Combined by an immunofluorescent analysis of the actin cytoskeleton, cell-cell junctions, cell-matrix adhesions, and matrix reorganization these results revealed a distinct balance of laminar shear stress, cell-cell contacts and substrate-matrix anchorage in affecting endothelial cell fate under flow conditions. This analysis underlines the importance of materials surface parameters as well as primary and secondary adhesion ligand anchorage in the context of artificial blood vessels for future therapeutic devices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2011.11.017DOI Listing

Publication Analysis

Top Keywords

shear stress
16
endothelial cells
16
endothelial cell
8
anchorage endothelial
8
blood vessels
8
adhesion ligand
8
revealed distinct
8
substrate-matrix anchorage
8
cells
6
shear
5

Similar Publications

Local hemodynamics play an essential role in the initiation and progression of coronary artery disease. While vascular geometry alters local hemodynamics, the relationship between vascular structure and hemodynamics is poorly understood. Previous computational fluid dynamics (CFD) studies have explored how anatomy influences plaque-promoting hemodynamics.

View Article and Find Full Text PDF

Aim: Branch atheromatous disease (BAD), characterized by the occlusion of perforating branches near the orifice of a parent artery, often develops early neurological deterioration because the mechanisms underlying BAD remain unclear. Abnormal wall shear stress (WSS) is strongly associated with endothelial dysfunction and plaque growth or rupture. Therefore, we hypothesized that computational fluid dynamics (CFD) modeling could detect differences in WSS between BAD and small-vessel occlusion (SVO), both of which result from perforating artery occlusion/stenosis.

View Article and Find Full Text PDF

The stability of kinetic-level convection cells (wherein the magnitude of macroscopic and microscopic velocities are of same order) is studied in a two-dimensional Yukawa liquid under the effect of microscopic velocity perturbations. Our numerical experiments demonstrate that for a given system aspect ratio β viz., the ratio of system length [Formula: see text] to its height [Formula: see text] and number of convective rolls initiated [Formula: see text], the fate of the convective cells is decided by [Formula: see text].

View Article and Find Full Text PDF

Loess is extensively developed on both sides of the Longwu River, a tributary of the Yellow River, Tongren County, Qinghai Province. The engineering geological characteristics are complex, and landslide disasters are highly developed. Based on field geological surveys and physical property analysis of the loess in this area, this study analyzes the influence of water content, consolidation pressure, and soil disturbance on the dynamic characteristics of loess using GDS dynamic triaxial tests.

View Article and Find Full Text PDF

Poly-N-isopropylacrylamide (PNIPAm), a thermorresponsive polymer, highly soluble in water below its lower critical solution temperature (LCST), is widely used in biomedical applications like drug delivery. Being able to measure PNIPAm size and aggregation state in solution quickly, inexpensively, and accurately below the LCST is critical when stoichiometric particle or molecular ratios are required. Dynamic light scattering (DLS) is probably the most widely available, and inexpensive nanoparticle sizing technique, but there are limitations with respect to sample polydispersity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!