A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An electromagnetic navigation system for transbronchial interventions with a novel approach to respiratory motion compensation. | LitMetric

Purpose: Bronchoscopic interventions, such as transbronchial needle aspiration (TBNA), are commonly performed procedures to diagnose and stage lung cancer. However, due to the complex structure of the lung, one of the main challenges is to find the exact position to perform a biopsy and to actually hit the biopsy target (e.g., a lesion). Today, most interventions are accompanied by fluoroscopy to verify the position of the biopsy instrument, which means additional radiation exposure for the patient and the medical staff. Furthermore, the diagnostic yield of TBNA is particularly low for peripheral lesions.

Methods: To overcome these problems the authors developed an image-guided, electromagnetic navigation system for transbronchial interventions. The system provides real time positioning information for the bronchoscope and a transbronchial biopsy instrument with only one preoperatively acquired computed tomography image. A twofold respiratory motion compensation method based on a particle filtering approach allows for guidance through the entire respiratory cycle. In order to evaluate our system, 18 transbronchial interventions were performed in seven ventilated swine lungs using a thorax phantom.

Results: All tracked bronchoscope positions were corrected to the inside of the tracheobronchial tree and 80.2% matched the correct bronchus. During regular respiratory motion, the mean overall targeting error for bronchoscope tracking and TBNA needle tracking was with compensation on 10.4 ± 1.7 and 10.8 ± 3.0 mm, compared to 14.4 ± 1.9 and 13.3 ± 2.7 mm with compensation off. The mean fiducial registration error (FRE) was 4.2 ± 1.1 mm.

Conclusions: The navigation system with the proposed respiratory motion compensation method allows for real time guidance during bronchoscopic interventions, and thus could increase the diagnostic yield of transbronchial biopsy.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.3662871DOI Listing

Publication Analysis

Top Keywords

respiratory motion
16
navigation system
12
system transbronchial
12
transbronchial interventions
12
motion compensation
12
electromagnetic navigation
8
bronchoscopic interventions
8
biopsy instrument
8
diagnostic yield
8
real time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!