Introduction: Hemolysis is still the most common reason for rejecting samples, while reobtaining a new sample is an important problem. The aim of this study was to investigate the effects of hemolysis in different hemolysis levels for mostly used biochemical parameters to prevent unnecessary rejections.

Materials And Methods: Sixteen healthy volunteers were enrolled in the study. Four hemolysis levels were constituted according to hemoglobin concentrations and they were divided into five groups: Group I: 0-0.10 g/L, Group II:0.10-0.50 g/L, Group III: 0.51-1.00 g/L, Group IV: 1.01-2.50 g/L, Group V: 2.51-4.50 g/L. Lysis was achieved by mechanical trauma.

Results: Hemolysis interference affected lactate dehydrogenase (LD) and aspartate aminotransferase (AST) almost at undetectable hemolysis by visual inspection (plasma hemoglobin < 0.5 g/L). Clinically meaningful variations of potassium and total bilirubin were observed in moderately hemolyzed samples (hemoglobin > 1 g/L). Alanine aminotransferase (ALT), cholesterol, gamma glutamyltransferase (GGT), and inorganic phosphate (P) concentrations were not interfered up to severely hemolyzed levels (hemoglobin: 2.5-4.5 g/L). Albumin, alkaline phosphatase (ALP), amylase, chloride, HDL-cholesterol, creatine kinase (CK), glucose, magnesium, total protein, triglycerides, unsaturated iron binding capacity (UIBC) and uric acid differences were statistically significant, but remained within the CLIA limits.

Conclusion: To avoid preanalytical visual inspection for hemolysis detection, improper sample rejection, and/or rerun because of hemolysis, it is recommended in this study that, routine determination of plasma or serum free hemoglobin concentrations is important. For the analytes interfered with hemolysis, new samples have to be requested.

Download full-text PDF

Source
http://dx.doi.org/10.11613/bm.2011.015DOI Listing

Publication Analysis

Top Keywords

g/l group
16
hemolysis
9
effects hemolysis
8
hemolysis levels
8
hemoglobin concentrations
8
g/l
8
visual inspection
8
hemoglobin g/l
8
hemoglobin
5
group
5

Similar Publications

Introduction: Chronic inflammation is a major risk factor for coronary artery disease (CAD). Currently, the inflammatory cardiovascular risk is assessed via C-reactive protein (CRP) levels measured using a high-sensitivity assay (hsCRP). Monomeric CRP (mCRP) is a locally produced form of CRP that has emerged as a potential biomarker of inflammation.

View Article and Find Full Text PDF

Environmental concerns stemming from the widespread use of polyethylene packaging and the perishability of fresh products have promoted the development of antimicrobial biodegradable packaging films in preservation of vegetables. In this study, antimicrobial films based on chitosan (CS)-nisin (Ni)-nanocrystalline cellulose (NCC) were characterized, and its preservation effect applied to baby cabbage was investigated. The results suggest that 1 % CS-0.

View Article and Find Full Text PDF

This study thoroughly investigated the adsorption of Congo Red (CR) dye onto various microplastics (MPs), including high-density polyethylene (HDPE), polyvinyl chloride (PVC), low-density polyethylene (LDPE), polypropylene (PP) and polyethylene terephthalate (PET). Initial adsorption capacities (q) revealed that HDPE had the highest value (21.90 mg/g), followed by PVC (4.

View Article and Find Full Text PDF

Pregnancy and COVID-19: Comparing ICU Outcomes for Pregnant and Nonpregnant Women.

Viruses

December 2024

Clinical Department of Anesthesiology and Intensive Therapy, Wroclaw Medical University, Borowska 213, 50-556 Wroclaw, Poland.

Background: This study compares organ dysfunction, treatment strategies, and unfavorable outcome rates between pregnant and nonpregnant women admitted to the ICU with severe COVID-19, highlighting the increased susceptibility of pregnant women to respiratory infections due to physiological changes.

Methods: A retrospective, age-matched study was conducted at a referral center specializing in critical care for pregnant women. Data from 14 pregnant/postpartum and 11 nonpregnant women were analyzed at ICU admission and on days 3, 5, and 7.

View Article and Find Full Text PDF

Effluents containing synthetic anionic dyes can pose a risk to ecosystems, and they must be treated before their release to the environment. Biosorption, a simple and effective process, may be a promising solution for treating these effluents. In this work, chitosan beads were crosslinked with epichlorohydrin to produce a highly stable and performant biosorbent to remove Brilliant Blue FCF dye.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!