Background: The aim of this prospective study was to evaluate safety and efficacy of the NiTi ColonRing™ for anastomoses on the colon or rectum.
Methods: During the period September 2008-June 2011, anastomosis using the NiTi ColonRing™ was scheduled to be performed on 60 patients (36 females, 24 males/mean aged 67 years), 53 of whom underwent colectomy for cancer and 7 reconstruction after Hartmann's procedure. Application of the device failed in one case due to anatomical reasons. Colorectal resections performed were as follows: Right hemicolectomy (5 patients), left colectomy (2), sigmoidectomy (15) and low anterior resection (31). A follow-up clinic visit after 1 month was planned for all patients. Ten patients among the first 14 had rectosigmoidoscopy at 2-3 months. All cancer patients were scheduled for colonoscopy at 12 months.
Results: No intraoperative or postoperative bleeding related to the anastomotic technique was recorded. Median hospital stay after surgery was 10.2 days (9-22 days). One patient died on day 13 due to myocardial infarction. Clinically apparent leak was detected in one patient who had undergone reconstruction after Hartmann; the only treatment required was total parenteral nutrition for 12 days. Anastomotic stenosis occurred in another one patient who had undergone reconstruction after Hartmann; it was easily resolved by balloon dilatation. Mild complications were encountered in 23 other patients (39%). Oral feeding started after day 4. Anastomotic rings were expelled naturally within 7-17 days (mean, 9.2 days). A satisfactory anastomosis was revealed in patients examined colonoscopically at 2-3 and 12 months. Mean follow-up was 15.2 months (2-33 months).
Conclusions: NiTi ColonRing™ is reliable, safe and efficacious for large bowel anastomoses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10151-011-0794-1 | DOI Listing |
Microsc Res Tech
January 2025
Faculty of Dental Medicine, Grigore T. Popa University of Medicine and Pharmacy, Iasi, Romania.
One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.
View Article and Find Full Text PDFNanomaterials (Basel)
January 2025
School of Civil Engineering, Wuhan University, Wuhan 430072, China.
Fracture toughness is a critical indicator for the application of NiTi alloys in medical fields. We propose to enhance the fracture toughness of NiTi alloys by controlling the spatial grain size (GS) gradient. Utilizing rolling processes and heat treatment technology, three categories of NiTi alloys with distinct spatial GS distributions were fabricated and subsequently examined through multi-field synchronous fracture tests.
View Article and Find Full Text PDFClin Pract
December 2024
Academic Area of Dentistry of Health Sciences Institute, Autonomous University of Hidalgo State, Exhacienda de la Concepción S/N Carretera Actopan-Tilcuautla, Tilcuautla C.P. 42160, Hidalgo, Mexico.
Background/objectives: The damage assessment of dental instruments, such as endodontic files, is crucial to ensure patient safety and treatment quality. Conventional scanning electron microscopy (SEM) has been the gold standard for this purpose; however, its limited accessibility and complex sample preparation protocols hinder its routine use in clinical settings. This study proposes a novel system that leverages digital photography and advanced image processing techniques as a viable alternative to SEM.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Dental and Life Science Institute, Pusan National University, Yangsan, Korea.
Background: This study compared the torsional resistance, bending stiffness, and cyclic fatigue resistances of different heat-treated NiTi files for minimally invasive instrumentation.
Methods: TruNatomy (TN) and EndoRoad (ER) file systems were compared with ProTaper Gold (PG). Torsional load, distortion angle, and bending stiffness were assessed using a custom device AEndoS, and toughness was calculated using the torsional data.
Colloids Surf B Biointerfaces
January 2025
Institute of Biomedical Engineering, College of Medicine, Key Laboratory of Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu 610031, China. Electronic address:
Neurovascular flow-diverting stents (FDSs) are revolutionizing the paradigm for treatment of intracranial aneurysms, but they still face great challenges like post- implantation acute thrombosis and delayed reendothelialization. Surface modification is of crucial relevance in addressing such key issues. In this study, we fabricated an ultrathin nanocoating out of copper (II) together with protocatechuic acid (PCA) and nattokinase (NK) bioactive molecules on NiTi FDSs via a coordination chemistry approach, with favorable biophysiochemical interactions, to fulfill this goal.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!