Study Design: This study evaluated the anatomical parameters of the lower cervical spine by imaging methods and reported a case.

Objective: To explain low neurovascular injury rate and provide some suggestions in cervical transpedicular screw fixation (CTSF).

Summary Of Background Data: Because of anatomical complexity and possible severe complications, application of CTSF was limited. However, recent studies have indicated that although cervical pedicular screw perforations may happen, severe complications seldom occur.

Methods: In 20 patients, several anatomical parameters were obtained on computed tomographic angiography (CTA) images of C3-C6, including the inner diameter of vertebral artery (d), the maximal width (A) and height (B) of the transverse foramen, the shortest distance between vertebral artery and cervical pedicle (h), and the angle between the longitudinal axis of pedicle and the hypothetical screw that just touches the vertebral artery (largest safe angle, LSA). Another 35 patients were chosen to measure the shortest distance between cervical pedicle and cervical spinal cord (H) and the angle between the longitudinal axis of pedicle and the hypothetical screw that just touches the cervical spinal cord (smallest angle, SA) on magnetic resonance imaging (MRI) of C4-C7.

Results: Between the left and the right sides, there was no statistically significant difference for d, A, B, h, and LSA at C3-C6 or H and SA at C4-C7. d, h, and H were, respectively, 3.97 ± 0.65 mm, 0.89 ± 0.44 mm, and 6.56 ± 2.10 mm, and there was no statistically significant difference among C3-C6 for d and h or among C4-C7 for H. LSA at C6 was larger than that at C3, C4, and C5; it increased from C5 to C7.

Conclusion: There was an "escaping space" for the vertebral artery and spinal cord. CTSF in the superior part of pedicle was relatively safer from accidental perforation of the vertebral artery than CTSF in the inferior part, and in C6 and C7, CTSF was safer from this injury than in C3, C4, and C5.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0b013e31821a5240DOI Listing

Publication Analysis

Top Keywords

vertebral artery
20
spinal cord
12
transpedicular screw
8
screw fixation
8
cervical
8
lower cervical
8
cervical spine
8
anatomical parameters
8
severe complications
8
shortest distance
8

Similar Publications

Percutaneous vertebroplasty (PVP) is a widely utilized minimally invasive technique originally developed for the treatment of vertebral compression fractures. It has since expanded to treat osteoporotic vertebral compression fractures, pathologic vertebral fractures resulting from primary or secondary spinal tumors, and traumatic spinal fractures. Despite its benefits, PVP is associated with significant complications, the most common of which is bone cement leakage.

View Article and Find Full Text PDF

Proximal protection devices for carotid artery stenting - A benchtop assessment of flow reversal performance.

AJNR Am J Neuroradiol

January 2025

From the Department of Radiology (J.L., E.A.B., C.B., J.C., R.K., W.B., D.F.K), and Department of Neurologic Surgery (Y.C.S., R.K., W.B.), Mayo Clinic, Rochester, MN, United States; Department of Stroke Research (J.L.), Vall d'Hebron Research Institute, Barcelona, Spain; From the Global Institute of Future Technology (Y.L.), Shanghai Jiao Tong University, Shanghai, China; Department of Neurointerventional Radiology (J.C.), Bicetre University Hospital, Le Kremlin Bicetre, France.

Background And Purpose: Proximal protection devices, such as TransCarotid Artery Revascularization (TCAR, SilkRoad Medical, Sunnyvale), aim to yield better outcomes in carotid artery stenting (CAS) than distal protection devices by preventing plaque embolization to the brain. However, transfemoral catheters may not fully reverse flow from the external carotid artery (ECA) to the internal carotid artery (ICA). We assess a new balloon-sheath device, Femoral Flow Reversal Access for Carotid Artery Stenting (FFRACAS), for this purpose.

View Article and Find Full Text PDF

A reduction in cerebral blood flow (CBF) has been observed during spaceflight and bed rest. We aimed to examine the magnitude and regional heterogeneity of the decrease in CBF during bed rest compared to posture changes on Earth. Seventeen participants (age, 29 ± 9 years, 7 females) were studied in the upright and supine posture and over 3 days of bed rest.

View Article and Find Full Text PDF

Cardiac allograft vasculopathy (CAV) remains a significant challenge after heart transplantation, necessitating effective surveillance methods. This review centers around the role of coronary computed tomography angiography (CCTA) in CAV surveillance, given its unique capabilities to visualize and quantify CAV in comparison with other imaging modalities, including invasive coronary angiography and intravascular ultrasound. CCTA has shown good diagnostic performance for detecting and monitoring CAV, exemplified by a higher sensitivity and negative predictive value compared with invasive coronary angiography.

View Article and Find Full Text PDF

Aberrant anatomical variation of the vertebral artery (VA) from an internal carotid artery (ICA) is considered a rare finding. The incidence of this phenomenon can lead to patients suffering from posterior circulation neurological deficit if the ICA becomes significantly diseased. VA atypical anatomical origin is considered one of the rare pathologies, not only precipitating neurovascular incidents but equally leading to severe difficulty in VA dissection and surgical exposure, especially in carotid artery procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!