A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of colonoscopy preparation quality on adenoma detection rates. | LitMetric

Background: Colonoscopy reduces the risk of colorectal cancer mortality by removing precancerous adenomas. The detection rate of subcentimeter (<10 mm) polyps is lower for procedures with inadequate preparation quality.

Objective: To compare the adenoma detection rates of small (6-9 mm) and diminutive (≤ 5 mm) adenomas in patients with poor and fair quality preparations with those with adequate quality preparations.

Design: Cross-sectional study and multivariable, hierarchical model.

Setting: Roudebush Veterans Affairs Medical Center.

Patients: This study involved 8800 colonoscopies performed from 2001 to 2010.

Main Outcome Measurements: Preparation quality rating, polyp size, and polyp histology.

Results: Preparation quality was rated as fair in 2809 (31.9%) and poor in 829 (9.4%) colonoscopies. In patients with poor compared with adequate quality, the detection rate was lower for diminutive adenomas (odds ratio [OR] 0.57; 95% CI, 0.47-0.70) but not for small adenomas (OR 0.84; 95% CI, 0.65-1.07). There were no differences in the detection rate of diminutive (OR 1.08; 95% CI, 0.94-1.24]) or small (OR 1.09; 95% CI, 0.94-1.27) adenomas in patients with fair compared with adequate quality preparation. Detection of advanced histology in patients with poor preparation quality was lower than in those with adequate quality (P = .027; 3.3% vs 5.0%), but there was no difference in those with fair compared with adequate quality (P = .893; 4.9% vs 5.0%).

Limitations: Single-center study; no standardization of preparation quality or size measurements.

Conclusions: A fair preparation quality rating does not decrease the detection rate for adenomas of any size or for advanced histology, suggesting that fair quality may be considered adequate and that follow-up intervals may not need to be shortened. Poor preparation quality decreases the detection rate of diminutive adenomas and advanced histology, suggesting substandard colonoscopy performance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2011.09.022DOI Listing

Publication Analysis

Top Keywords

colonoscopy preparation
4
preparation quality
4
quality adenoma
4
adenoma detection
4
detection rates
4
rates background
4
background colonoscopy
4
colonoscopy reduces
4
reduces risk
4
risk colorectal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!