A sensitive spectrofluorimetric method has been developed for the determination of moxifloxacin (MOX) using europium(III)-MOX complex as a fluorescence probe in the presence of an anionic surfactant, sodium dodecyl benzene sulfonate (SDBS). The fluorescence (FL) intensity of Eu(3+) was enhanced by complexation with MOX at 614 nm after excitation at 373 nm. The FL intensity of the Eu(3+)-MOX complex was significantly intensified in the presence of SDBS. Under the optimum conditions, it was found that the enhanced FL intensity of the system showed a good linear relationship with the concentration of MOX over the range of 1.8 × 10(-11)-7.3 × 10(-9) g mL(-1) with a correlation coefficient of 0.9998. The limit of detection of MOX was found to be 2.8 × 10(-12) g mL(-1) with relative standard deviation (RSD) of 1.25% for 5 replicate determination of 1.5 × 10(-8) g mL(-1) MOX. The proposed method is simple, offers higher sensitivity with wide linear range and can be successfully applied to determine MOX in pharmaceutical and biological samples with good reproducibility. The luminescence mechanism is also discussed in detail with ultraviolet absorption spectra.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2011.10.051DOI Listing

Publication Analysis

Top Keywords

mox
6
spectrofluorimetric study
4
study interaction
4
interaction europiumiii
4
europiumiii moxifloxacin
4
moxifloxacin micellar
4
micellar solution
4
solution analytical
4
analytical application
4
application sensitive
4

Similar Publications

Cyathostomins are the most abundant equid endoparasites globally. There are approximately fifty cyathostomin species and, whilst they occupy distinct niches within the large intestine, they are generally considered to share similar characteristics in terms of pathogenicity and response to drug treatment. There are three classes of anthelmintic licensed in the UK to treat cyathostomins (benzimidazoles, tetrahydropyrimidines and macrocyclic lactones) and cases of resistance have been documented for all classes.

View Article and Find Full Text PDF

Infrared Spectroscopic Electronic Noses: An Innovative Approach for Exhaled Breath Sensing.

ACS Sens

January 2025

Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.

Gastric cancer remains a leading cause of cancer-related mortality, requiring the urgent development of innovative diagnostic tools for early detection. This study presents an integrated infrared spectroscopic electronic nose system, a novel device that combines infrared (IR) spectroscopy and electronic nose (eNose) concepts for analyzing volatile organic compounds (VOCs) in exhaled breath. This system was calibrated using relevant gas mixtures and then tested during a feasibility study involving 26 gastric cancer patients and 32 healthy controls using chemometric analyses to distinguish between exhaled breath profiles.

View Article and Find Full Text PDF

Physical Activity and Frailty Are Impaired in Older Adults with Benign Paroxysmal Positional Vertigo.

J Clin Med

December 2024

Faculty of Rehabilitation Sciences, REVAL-Rehabilitation Research Centre, Hasselt University, 3590 Diepenbeek, Belgium.

: Benign Paroxysmal Positioning Vertigo (BPPV), diagnosed in 46% of older adults with complaints of dizziness, causes movement-related vertigo. This case-control study compared physical activity, frailty and subjective well-being between older adults with BPPV (oaBPPV) and controls. : Thirty-seven oaBPPV (mean age 73.

View Article and Find Full Text PDF

Background/objectives: Measuring the physical functioning of older hip fracture patients using wearables is desirable, with physical activity monitoring offering a promising approach. However, it is first important to assess physical activity in healthy older adults. This study quantifies physical functioning with physical activity parameters and assesses those parameters in community-dwelling older adults.

View Article and Find Full Text PDF

This paper presents a comprehensive and detailed analysis of the OECD-NEA MOX fuel benchmark based on different nuclear data libraries to investigate the reliability and accuracy of the Dragon5 lattice code developed by École Polytechnique de Montréal for the neutronic analysis of mixed uranium-plutonium oxide (MOX) fuel. The neutronics and burn-up calculations for rectangular pin and assembly geometries filled with different compositions of MOX fuel are computed. The performance of different nuclear data libraries is evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!