In experimental RG1 2.2 glioma of rat brain, local blood flow, glucose utilization, protein synthesis, glucose and ATP content were measured by means of triple tracer autoradiography and bioluminescence technique, respectively, to determine hemodynamic and metabolic thresholds for local tumor energy failure. Perfusion thresholds were estimated at tumor blood flow values of 69.0 +/- 0.1 ml/100 g/min (estimate +/- standard error) and of 69 +/- 7.1 ml/100 g/min for the beginning of the decline in regional ATP and glucose content, respectively. Metabolic thresholds were derived at tumor glucose utilization values of 70.6 +/- 8.3 mumol/100 g/min for reduced protein synthesis, of 55.0 +/- 0.2 mumol/100 g/min for the decrease in glucose content, and 34.7 +/- 4.7 mumol/100 g/min for decline in ATP content. Our results suggest that blood flow limits glucose supply to tumor tissue at much higher flow rates than in normal brain which, in turn, is associated with a decrease in tumor glucose utilization. A reduction and not an increase in tumor glucose availability could be a more appropriate strategy for the induction of energy failure in tumors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF00167064 | DOI Listing |
Afr J Reprod Health
December 2024
Department of Medical Laboratory, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan 646000, China.
This was an original article, and the objective of this study was to investigate the effects of bipolar transurethral plasma kinetic prostatectomy (TUPKP) on urodynamics and sexual function in benign prostatic hyperplasia (BPH) patients. One hundred and four BPH patients were divided into a control group and an intervention group. The control group received transurethral resection of prostate, while the intervention group received TUKEP.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Division of Neurological Rehabilitiation, Instituto Nacional de Rehabilitacion Luis Guillermo Ibarra Ibarra, Mexico City 14389, Mexico.
Stroke is a global health issue caused by reduced blood flow to the brain, which leads to severe motor disabilities. Measuring oxygen levels in the brain tissue is crucial for understanding the severity and evolution of stroke. While CT or fMRI scans are preferred for confirming a stroke due to their high sensitivity, Near-Infrared Spectroscopy (NIRS)-based systems could be an alternative for monitoring stroke evolution.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Biomedical Engineering, Price Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada.
Monitoring cerebral oxygenation and metabolism, using a combination of invasive and non-invasive sensors, is vital due to frequent disruptions in hemodynamic regulation across various diseases. These sensors generate continuous high-frequency data streams, including intracranial pressure (ICP) and cerebral perfusion pressure (CPP), providing real-time insights into cerebral function. Analyzing these signals is crucial for understanding complex brain processes, identifying subtle patterns, and detecting anomalies.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Beijing Tsinghua Changgung Hospital Affiliated to Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.
The monitoring of peripheral circulation, as indicated by the capillary refill time, is a sensitive and accurate method of assessing the microcirculatory status of the body. It is a widely used tool for the evaluation of critically ill patients, the guidance of therapeutic interventions, and the assessment of prognosis. In recent years, there has been a growing emphasis on microcirculation monitoring which has led to an increased focus on capillary refill time.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Internal Medicine, Kanai Hospital, 612-12, Yodokizu-cho, Fushimi-ku, Kyoto 613-0911, Japan.
Diabetes is known to reduce blood circulation in capillaries and arterioles; however, no devices can easily measure this on a daily basis. In this study, we developed a tool for measuring finger photoplethysmograms using green light and near-infrared LEDs. Thereafter, photoplethysmography was conducted on 25 inpatients/outpatients with diabetes and 21 adult males and females who had not been diagnosed with or treated for diabetes, hypertension, or cardiovascular disease (control group).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!