Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: When aortic valve replacement (AVR) is performed in patients with a small aortic annulus, prosthesis-patient mismatch (PPM) is of concern. We investigated the mid-term outcomes of AVR with a 17-mm mechanical prosthesis.
Methods And Results: Seventy-eight patients with aortic stenosis underwent AVR with a 17-mm St. Jude Medical Regent prosthesis. Echocardiography was performed preoperatively, at discharge, and at follow-up (mean follow-up, 33 months). Patients were divided into 2 groups: with and without PPM at discharge. Between-group differences in postoperative variables, particularly survival, were analyzed. Overall hospital mortality was 2.6%. Actuarial 1- and 5-year survival rates were 95% and 79%, respectively. Diabetes and renal insufficiency were associated with long-term mortality. Freedom from major adverse valve-related cardiac events at 1 year and 5 years was 97.3% and 93.9%, respectively. Diabetes was shown to be an independent risk factor for major adverse valve-related cardiac events. Echocardiography 13 months after AVR showed a significant increase in mean effective orifice area index, decrease in mean left ventricular-aortic pressure gradient, and decrease in mean left ventricular mass index. PPM at discharge did not influence long-term survival or left ventricular mass regression.
Conclusions: The 17-mm Regent prosthesis provided satisfactory clinical and hemodynamic results. It is a reliable choice for patients with a small aortic annulus.