A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mid-term outcomes after aortic valve replacement with the 17-mm St. Jude Medical Regent valve. | LitMetric

Background: When aortic valve replacement (AVR) is performed in patients with a small aortic annulus, prosthesis-patient mismatch (PPM) is of concern. We investigated the mid-term outcomes of AVR with a 17-mm mechanical prosthesis.

Methods And Results: Seventy-eight patients with aortic stenosis underwent AVR with a 17-mm St. Jude Medical Regent prosthesis. Echocardiography was performed preoperatively, at discharge, and at follow-up (mean follow-up, 33 months). Patients were divided into 2 groups: with and without PPM at discharge. Between-group differences in postoperative variables, particularly survival, were analyzed. Overall hospital mortality was 2.6%. Actuarial 1- and 5-year survival rates were 95% and 79%, respectively. Diabetes and renal insufficiency were associated with long-term mortality. Freedom from major adverse valve-related cardiac events at 1 year and 5 years was 97.3% and 93.9%, respectively. Diabetes was shown to be an independent risk factor for major adverse valve-related cardiac events. Echocardiography 13 months after AVR showed a significant increase in mean effective orifice area index, decrease in mean left ventricular-aortic pressure gradient, and decrease in mean left ventricular mass index. PPM at discharge did not influence long-term survival or left ventricular mass regression.

Conclusions: The 17-mm Regent prosthesis provided satisfactory clinical and hemodynamic results. It is a reliable choice for patients with a small aortic annulus.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.cj-11-0733DOI Listing

Publication Analysis

Top Keywords

mid-term outcomes
8
aortic valve
8
valve replacement
8
17-mm jude
8
jude medical
8
medical regent
8
patients small
8
small aortic
8
aortic annulus
8
avr 17-mm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!