Colloid retention at the meniscus-wall contact line in an open microchannel.

Water Res

Department of Biological & Environmental Engineering, Riley-Robb Hall, Cornell University, Ithaca, NY 14853-5701, USA.

Published: February 2012

Colloid retention mechanisms in partially saturated porous media are currently being researched with an array of visualization techniques. These visualization techniques have refined our understanding of colloid movement and retention at the pore scale beyond what can be obtained from breakthrough experiments. One of the remaining questions is what mechanisms are responsible for colloid immobilization at the triple point where air, water, and soil grain meet. The objective of this study was to investigate how colloids are transported to the air-water-solid (AWS) contact line in an open triangular microchannel, and then retained as a function of meniscus contact angle with the wall and solution ionic strength. Colloid flow path, meniscus shape and meniscus-wall contact angle, and colloid retention at the AWS contact line were visualized and quantified with a confocal microscope. Experimental results demonstrated that colloid retention at the AWS contact line was significant when the meniscus-wall contact angle was less than 16°, but was minimal for the meniscus-wall contact angles exceeding 20°. Tracking of individual colloids and computational hydrodynamic simulation both revealed that for small contact angles (e.g., 12.5°), counter flow and flow vortices formed near the AWS contact line, but not for large contact angles (e.g., 28°). This counter flow helped deliver the colloids to the wall surface just below the contact line. In accordance with DLVO and hydrodynamic torque calculations, colloid movement may be stopped when the colloid reached the secondary minimum at the wall near the contact line. However, contradictory to the prediction of the torque analysis, colloid retention at the AWS contact line decreased with increasing ionic strength for contact angles of 10-20°, indicating that the air-water interface was involved through both counter flow and capillary force. We hypothesized that capillary force pushed the colloid through the primary energy barrier to the primary minimum to become immobilized, when small fluctuations in water level stretched the meniscus over the colloid. For large meniscus-wall contact angles counter flow was not observed, resulting in less colloid retention, because a smaller number of colloids were transported to the contact line.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2011.09.046DOI Listing

Publication Analysis

Top Keywords

colloid retention
24
meniscus-wall contact
20
aws contact
20
contact angles
20
contact
17
counter flow
16
colloid
13
contact angle
12
retention aws
12
contact open
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!