The standard α(s)-data of N(2) at 87.3 K by graphitized and nongraphitized carbon black samples (GCB-I and NGCB) (cf.Figs. 3 and 4) have been determined on the basis of the high resolution adsorption isotherms of N(2) at 87.3 K, which were repeatedly measured in the pressure range of p/p(o)=5×10(-8)-0.4. The high resolution adsorption isotherms of N(2) by two kinds of activated carbon fibers (ACF-I and ACF-II) were measured from p/p(o)=10(-7) to p/p(o)=0.995 at 77.4 K and from p/p(o)=10(-7) to p/p(o)=0.4 at 87.3 K. Combination of the adsorption isotherms by ACF-I and ACF-II with the standard α(s)-data by NGCB at 77.4 K and 87.3 K make it possible to construct the high resolution α(s)-plots from very low filling (1%) to complete filling (100%). The high resolution α(s)-plots of N(2) at 77.4 K and 87.3 K were analyzed. On the basis of the analyzed result, the porous textures of ACF-I and ACF-II will be discussed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcis.2011.10.061 | DOI Listing |
Adv Rheumatol
January 2025
Division of Rheumatology, Department of Internal Medicine, Kocaeli University Faculty of Medicine, İzmit, Kocaeli, 41380, Turkey.
Background: The clinical manifestations and course of rheumatoid arthritis-associated interstitial lung disease (RA-ILD) exhibits considerable heterogeneity. In this study, we aimed to explore radiographic progression over a defined period, employing the Warrick score as a semi-quantitative measure in early RA-ILD, and to assess the associated risk factors for progression.
Methods: RA-ILD patients underwent consecutive Warrick scoring based on initial high-resolution computed tomography (HRCT) at diagnosis and the first follow-up.
Eur Arch Otorhinolaryngol
January 2025
Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy, 54000, France.
Background And Purpose: To evaluate various anatomical parameters and their relationship to chorda tympani nerve (CTN) injury and round window (RW) access during cochlear implantation.
Materials And Methods: Ultra-high-resolution CT images of 66 patients were retrospectively reviewed and compared with operative reports. The facial recess and the round window were analyzed, mainly using the chorda-facial angle (CFA), the width of the facial recess, the CTN-tympanic annulus distance, the RW-mastoid portion of the facial nerve angle, and the type of RW.
NPJ Digit Med
January 2025
Graduate School of Data Science, Seoul National University, Seoul, Republic of Korea.
Polysomnography (PSG) is crucial for diagnosing sleep disorders, but manual scoring of PSG is time-consuming and subjective, leading to high variability. While machine-learning models have improved PSG scoring, their clinical use is hindered by the 'black-box' nature. In this study, we present SleepXViT, an automatic sleep staging system using Vision Transformer (ViT) that provides intuitive, consistent explanations by mimicking human 'visual scoring'.
View Article and Find Full Text PDFSci Rep
January 2025
Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA.
Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.
View Article and Find Full Text PDFNat Commun
January 2025
Department of Physics, Harvard University, Cambridge, MA, USA.
High-resolution fluorescence imaging of ultracold atoms and molecules is paramount to performing quantum simulation and computation in optical lattices and tweezers. Imaging durations in these experiments typically range from a millisecond to a second, significantly limiting the cycle time. In this work, we present fast, 2.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!