Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A method was developed for the simultaneous determination of 9 heterocyclic aromatic amines (HAAs) including 2-amino-3-methylimidazo[4,5-f] quinoline (IQ), 2-amino-3,4-dimethylimidazo[4, 5-f] quinoline (MeIQ), 2-amino-3, 8-dimethylimidazo [4, 5-f] quinoxaline (MeIQx), 2-amino-3, 4, 8-trimethyl-imidazo [4,5-f quinoxaline (4,8-DiMeIQx), 2-amino-1-methyl-6-phenylimidazo [4,5-b] pyridine (PhIP), 3-amino-1 -methyl-5H-pyrido [4, 3-b] indole (Trp-p-2), 3-amino-1, 4-dimethyl-5H-pyrido [4,3-b] indole (Trp-p-1), 9H-pyrido [3,4-b] indole (Norharman), 1-methyl-9H-pyrido 3, 4-b] indole (Harman)) in poultry products using solid-phase extraction-high performance liquid chromatography (SPE-HPLC). The performance of 3 different organic extraction solutions, 2 solid phase extraction (SPE) procedures, three different reversed-phase columns and five different mobile phases were tested for optimizing separation conditions of the 9 HAAs from poultry products. In the end, ethyl acetate was selected as the extraction solution, and the extract was purified with propylsulfonic acid silica (PRS) and C18 SPE columns. The analysis was performed on a TSK-gel ODS-80TM column using a gradient elution with the mobile phases of 0.05 mol/L aqueous acetic acid-ammonium acetate buffer (pH 3.4) and acetonitrile. The results showed that the average recoveries (n = 6) of the 9 HAAs spiked in meat samples at 3 levels ranged from 60.47% to 90.55% with the relative standard deviations (RSDs) between 0.49% and 9.74%, and the limits of detection (LODs, S/N = 3) were in the range of 0.1 - 3.6 microg/kg. The method is simple, rapid, accurate and sensitive enough for the analysis of HAAs in poultry products.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!