Purpose: To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures.
Materials And Methods: The catheter shaft incorporated Kevlar braiding. A 180° deflection was attained with a 5-cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine.
Results: Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF-induced heating in all configurations under expected use conditions in vitro and in vivo.
Conclusion: Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057" lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3292659 | PMC |
http://dx.doi.org/10.1002/jmri.23520 | DOI Listing |
Purpose: Anterior tibial closing wedge osteotomy (ATCWO) has been shown to significantly reduce failure rates of revision anterior cruciate ligament (ACL) reconstructions in patients with a posterior tibial slope (PTS) ≥12°. Recent findings suggest a slight but significant reduction of the medial proximal tibial angle (MPTA) resulting in a varus knee where the sagittal osteotomy plane is based on a total of two guide wires defining the osteotomy wedge without respecting the frontal plane. We hypothesize that the placement of a total of four guide wires intraoperatively can reduce the influence on the MPTA.
View Article and Find Full Text PDFData Brief
December 2024
Tampere University, Faculty of Built Environment, P.O. Box 600, FI-33014 Tampere, Finland.
In a slim-floor structural system, beams and slabs are placed at the same level, reducing the overall floor height and material usage in vertical structures, thereby improving economic efficiency. The use of slim-floor structures is common practice in Finnish construction where these structures are typically constructed using hollow-concrete slabs and welded steel box beams. However, in Finland, only a few buildings utilise cross-laminated timber (CLT) slabs in slim-floor structures, and none have incorporated the composite action between CLT and steel beams.
View Article and Find Full Text PDFSM Radiol J
June 2024
Department of Mechanical Engineering, University of Akron, Akron, OH, USA.
Prostate cancer ranks as the second most common cause of cancer-related mortality among males. A template guided core biopsy procedure is an essential component of prostate cancer diagnosis. Various factors influence the quality of the histological sample that is produced from the biopsy, including tissue fragmentation, needle insertion speed, needle deflection, and sheath cutting speed.
View Article and Find Full Text PDFHeart Rhythm O2
November 2024
Unidad Médica de Alta Especialidad en Pediatría, Centro Médico Nacional de Occidente, Instituto Mexicano del Seguro Social, Guadalajara, México.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!