Real time 3D visualization of intraoperative organ deformations using structured dictionary.

IEEE Trans Med Imaging

Department of Electrical and Computer Engineering, The University of Texas at Austin, 78712, USA.

Published: April 2012

Restricted visualization of the surgical field is one of the most critical challenges for minimally invasive surgery (MIS). Current intraoperative visualization systems are promising. However, they can hardly meet the requirements of high resolution and real time 3D visualization of the surgical scene to support the recognition of anatomic structures for safe MIS procedures. In this paper, we present a new approach for real time 3D visualization of organ deformations based on optical imaging patches with limited field-of-view and a single preoperative scan of magnetic resonance imaging (MRI) or computed tomography (CT). The idea for reconstruction is motivated by our empirical observation that the spherical harmonic coefficients corresponding to distorted surfaces of a given organ lie in lower dimensional subspaces in a structured dictionary that can be learned from a set of representative training surfaces. We provide both theoretical and practical designs for achieving these goals. Specifically, we discuss details about the selection of limited optical views and the registration of partial optical images with a single preoperative MRI/CT scan. The design proposed in this paper is evaluated with both finite element modeling data and ex vivo experiments. The ex vivo test is conducted on fresh porcine kidneys using 3D MRI scans with 1.2 mm resolution and a portable laser scanner with an accuracy of 0.13 mm. Results show that the proposed method achieves a sub-3 mm spatial resolution in terms of Hausdorff distance when using only one preoperative MRI scan and the optical patch from the single-sided view of the kidney. The reconstruction frame rate is between 10 frames/s and 39 frames/s depending on the complexity of the test model.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2011.2177470DOI Listing

Publication Analysis

Top Keywords

real time
12
time visualization
12
organ deformations
8
structured dictionary
8
visualization surgical
8
single preoperative
8
visualization
5
visualization intraoperative
4
intraoperative organ
4
deformations structured
4

Similar Publications

Background: The outcome of coronary artery bypass grafting (CABG) depends on several factors, including the quality of the distal anastomoses to the coronary arteries. Early graft failure may be caused by, e.g.

View Article and Find Full Text PDF

TiMON: a real-time integrated monitor for improving the placement and wear of emergency tourniquets.

BMC Emerg Med

January 2025

Wellman Center for Photomedicine, Harvard Medical School, Massachusetts General Hospital, CNY149, 13th St, Charlestown, 02129, MA, USA.

Background: The use of emergency tourniquets among military personnel has helped to dramatically reduce battlefield deaths and has recently gained popularity in the civilian sector. Yet, even well-trained individuals can find it difficult to assess proper tourniquet application. Emergency tourniquets are typically deemed sufficiently tightened through cursory visual confirmation or pulse assessment.

View Article and Find Full Text PDF

Aim: This study aimed to compare the prognostic performance of the risk models for patients with hepatocellular carcinoma (HCC) receiving atezolizumab and bevacizumab (Atez/Bev) as first-line treatment.

Methods: Among 449 patients included in this retrospective multicenter study, we compared the prognostic performance of 13 risk models for the 12-month and 18-month survival status using area under the curve (AUC), net reclassification improvement (NRI), and relative integrated discrimination improvement (IDI) analysis. We also constructed a calibration plot to assess the fitness of each model.

View Article and Find Full Text PDF

The I38T substitution in the influenza virus polymerase-acidic (PA) subunit is a resistance marker of concern for treatment with the antiviral baloxavir marboxil (BXM). Thus, monitoring PA/I38T mutations is of clinical importance. Here, we developed three rapid and sensitive assays for the detection and monitoring of the PA/I38T mutation.

View Article and Find Full Text PDF

Background: Neuroendocrine liver metastases (NELM) significantly reduce survival in patients with neuroendocrine tumor. The management of NELM is challenged by a low rate of resectability and a high rate of recurrence. Indocyanine green (ICG) fluorescence imaging offers potential advantages in real-time tumor visualization and margin assessment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!