A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of results for commercially available microbiological media plates with results for standard bacteriologic testing of bovine milk. | LitMetric

Objective: To compare results for 3 commercially available microbiological media plates with those for standard bacteriologic testing of bovine milk.

Sample: Milk samples from postpartum cows and cows with a high somatic cell count (SCC) or clinical mastitis (CM).

Procedures: Sample-ready Staphylococcus culture medium (SRSC) plates were used to detect Staphylococcus aureus in milk samples obtained from postpartum cows and cows with a high SCC or CM. Rapid coliform count (RCC) plates were used to detect coliforms in milk samples obtained from cows with CM. Aerobic count (AC) plates were used to detect streptococci in CM samples. Fresh mastitic milk samples were frozen and then thawed to evaluate the effects of freezing for the SRSC and RCC plates. The effects of dilution (1:10) of samples were determined. Agreement of results between the commercially available plates and standard bacteriologic testing was evaluated.

Results: The ability of SRSC plates to detect S aureus in milk samples was highest with diluted samples from postpartum cows and cows with a high SCC or CM. Sensitivity of the RCC plate for detection of coliforms was highest with diluted mastitic milk samples. The AC plates had a poor positive predictive value for detection of streptococci in mastitic milk samples. Freezing increased S aureus detection.

Conclusions And Clinical Relevance: Overall, the SRSC and RCC plates were accurate, were easy to use, and yielded results comparable to those of standard bacteriologic testing for the detection of S aureus and coliforms in bovine milk.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.72.12.1622DOI Listing

Publication Analysis

Top Keywords

milk samples
28
standard bacteriologic
16
bacteriologic testing
16
plates detect
16
plates standard
12
samples postpartum
12
postpartum cows
12
cows cows
12
cows high
12
rcc plates
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!