Repeated-dose studies received by the New Substances Assessment and Control Bureau (NSACB) of Health Canada are used to provide hazard information toward risk calculation. These studies provide a point of departure (POD), traditionally the NOAEL or LOAEL, which is used to extrapolate the quantity of substance above which adverse effects can be expected in humans. This project explored the use of benchmark dose (BMD) modeling as an alternative to this approach for studies with few dose groups. Continuous data from oral repeated-dose studies for chemicals previously assessed by NSACB were reanalyzed using U.S. EPA benchmark dose software (BMDS) to determine the BMD and BMD 95% lower confidence limit (BMDL(05) ) for each endpoint critical to NOAEL or LOAEL determination for each chemical. Endpoint-specific benchmark dose-response levels , indicative of adversity, were consistently applied. An overall BMD and BMDL(05) were calculated for each chemical using the geometric mean. The POD obtained from benchmark analysis was then compared with the traditional toxicity thresholds originally used for risk assessment. The BMD and BMDL(05) generally were higher than the NOAEL, but lower than the LOAEL. BMDL(05) was generally constant at 57% of the BMD. Benchmark provided a clear advantage in health risk assessment when a LOAEL was the only POD identified, or when dose groups were widely distributed. Although the benchmark method cannot always be applied, in the selected studies with few dose groups it provided a more accurate estimate of the real no-adverse-effect level of a substance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1539-6924.2011.01732.x | DOI Listing |
Appl Radiat Isot
January 2025
Medical Diagnostic Imaging Department, College of Health Science, University of Sharjah, Sharjah, United Arab Emirates.
Background: Bone scans using technetium-99m methylene diphosphonate (99mTc-MDP) are widely used in nuclear medicine for diagnosing various bone disorders. However, the radiation exposure associated with these procedures necessitates careful consideration and optimization.
Aim: This study aimed to evaluate radiation doses in terms of Effective Dose (ED) and establish Diagnostic Reference Levels (DRLs) for 99mTc-MDP bone scans in Saudi Arabia.
Phys Med Biol
January 2025
Department of Radiation Oncology, The University of Kansas Medical Center, Department of Radiation Oncology, University of Kansas Medical Center, USA, Kansas City, Kansas, 66160-8500, UNITED STATES.
Proton minibeam radiation therapy (pMBRT) dose profile is characterized by highly heterogeneous dose in the plane perpendicular to the beam direction and rapidly changing depth dose profiles. Typically, dose measurements are benchmarked against in-house Monte Carlo simulation tools. It is essential to have a treatment planning system (TPS) that can accurately predict pMBRT doses in tissue and be available via commercial platform for preclinical and clinical use.
View Article and Find Full Text PDFMed Biol Eng Comput
January 2025
Faculty of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel.
Positron emission tomography (PET) imaging plays a pivotal role in oncology for the early detection of metastatic tumors and response to therapy assessment due to its high sensitivity compared to anatomical imaging modalities. The balance between image quality and radiation exposure is critical, as reducing the administered dose results in a lower signal-to-noise ratio (SNR) and information loss, which may significantly affect clinical diagnosis. Deep learning (DL) algorithms have recently made significant progress in low-dose (LD) PET reconstruction.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
April 2025
Department of Radiology and Nuclear Medicine, University Teaching and Research Hospital Lucerne, Luzern, Switzerland.
Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).
Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.
Fish Shellfish Immunol
January 2025
College of Fisheries, Huazhong Agricultural University, Wuhan 430070, China; Engineering Research Center of Green Development for Conventional Aquatic Biological Industry in the Yangtze River Economic Belt, Ministry of Education, Wuhan, 430070, China; Hubei Provincial Engineering Laboratory for Pond Aquaculture, Wuhan, 430070, China; Freshwater Aquaculture Collaborative Innovation Center of Hubei Province, Wuhan, 430070, China. Electronic address:
Microcystin-leucine-arginine (MC-LR) has been shown to induce neuroinflammation and disrupt neurotransmitter system. However, little is known about the mechanism of toxicity. In this study, male adult zebrafish (Danio rerio) were exposed to MC-LR at concentrations of 0, 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!