BK channels are activated by intracellular Ca(2+) and Mg(2+) as well as by depolarization. Such activation is possible because each of the four subunits has two high-affinity Ca(2+) sites, one low-affinity Mg(2+) site, and a voltage sensor. This study further investigates the mechanism of Mg(2+) activation by using single-channel recording to determine separately the action of Mg(2+) on the open and closed states of the channel. To limit Mg(2+) action to the Mg(2+) sites, the two high-affinity Ca(2+) sites are disabled by mutation. When the voltage is stepped from negative holding potentials to +100 mV, we find that 10 mM Mg(2+) decreases the mean closed latency to the first channel opening 2.1-fold, decreases the mean closed interval duration 8.7-fold, increases mean burst duration 10.1-fold, increases the number of openings per burst 4.4-fold, and increases mean open interval duration 2.3-fold. Hence, Mg(2+) can bind to closed BK channels, increasing their opening rates, and to open BK channels, decreasing their closing rates. To explore the relationship between Mg(2+) action and voltage sensor activation, we record single-channel activity in macropatches containing hundreds of channels. Open probability (P(o)) is dramatically increased by 10 mM Mg(2+) when voltage sensors are activated with either depolarization or the mutation R210C. The increased P(o) arises from large decreases in mean closed interval durations and moderate increases in mean open interval durations. In contrast, 10 mM Mg(2+) has no detectable effects on P(o) or interval durations when voltage sensors are deactivated with very negative potentials or the mutation R167E. These observations are consistent with a model in which Mg(2+) can bind to and alter the gating of both closed and open states to increase P(o), provided that one or more voltage sensors are activated.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3226971 | PMC |
http://dx.doi.org/10.1085/jgp.201110707 | DOI Listing |
Sensors (Basel)
January 2025
School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China.
With the demand for high-safety, high-integration, and lightweight micro- and nano-electronic components, an MEMS electromagnetic energy-releasing component was innovatively designed based on the corona discharge theory. The device subverted the traditional device-level protection method for electromagnetic energy, realizing the innovation of adding a complex circuit system to the integrated chip through micro-nanometer processing technology and enhancing the chip's size from the centimeter level to the micron level. In this paper, the working performance of the MEMS electromagnetic energy-releasing component was verified through a combination of a simulation, a static experiment, and a dynamic test, and a characterization test of the tested MEMS electromagnetic energy-releasing component was carried out to thoroughly analyze the effect of the MEMS electromagnetic energy-releasing component.
View Article and Find Full Text PDFSensors (Basel)
January 2025
State Key Laboratory of Petroleum Resources and Prospecting, China University of Petroleum, Beijing 102249, China.
Transducers used in acoustic logging while drilling (ALWD) must be mounted on a drill collar, and their radiation performance is dependent on the employed mounting method. Herein, the complex transmitting voltage response of a while-drilling (WD) monopole acoustic source was calculated through finite-element harmonic-response analysis. Subsequently, the acoustic pressure waveform radiated by the source driven by a half-sine excitation voltage signal was calculated using the complex transmitting voltage response.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Electrical and Electronics Engineering, Faculty of Engineering, Karadeniz Technical University, Trabzon 61080, Türkiye.
Electric heaters are widely used owing to their portability, fast heating, single-focus heating, and energy efficiency advantages. Manufacturers provide customers with information on the power consumption and energy efficiency classes of heaters but do not provide any information on heating patterns. Knowing the heating pattern enables users to select the correct heater, which has a significant effect on comfort, health, energy efficiency, industrial process performance, plant growth, and climate change.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Faculty of Management, Lublin University of Technology, 20-618 Lublin, Poland.
This article presents the results of experimental studies on the influence of the geometry of high-voltage plasma actuator electrodes on the change in flow in the boundary layer and their influence on the change in the lift coefficient. The plasma actuator used in the described experimental studies has a completely different structure. The experimental model of the plasma actuator uses a large mesh ground electrode and different geometries of the high-voltage electrodes, namely copper solid electrodes and mesh electrodes (the use of mesh electrodes, large GND and HV is a new solution).
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Mechanical Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan.
Adhesive joining has the severe limitation that damages/defects developed in the bondline are difficult to assess. Conventional non-destructive examination (NDE) techniques are adequate to reveal disbonding defects in fabrication and delamination near the end of service life but are not helpful in detecting and monitoring in-service degradation of the joint. Several techniques suitable for long-term joint integrity monitoring are proposed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!