Background: Conduction disorders and permanent pacemaker (PPM) implantation are common complications in patients undergoing transcatheter aortic valve implantation (TAVI). Previous studies, evaluating small populations, have identified several different predictors of PPM implantation after TAVI. The aim of this study was to assess the incidence rate of conduction disorders and the predictors of postoperative PPM requirement in a large series of patients undergoing TAVI.

Methods: Data were analyzed from 181 consecutive patients at high-risk surgery who underwent TAVI at our institute between July 2007 and April 2011. All patients underwent implantation of the third-generation percutaneous self-expanding CoreValve® prosthesis (CoreValve, Inc., Irvine, CA, USA). In all patients, a 12-lead electrocardiogram and a 24-h holter monitoring was recorded before and after the procedure in order to assess the presence of conduction disorders. Clinical data, preoperative conduction disorders, echocardiographic patterns, and procedural data were tested as predictors of PPM implantation after TAVI.

Results: Left bundle branch block (LBBB) was the most common conduction disorder, with an incidence of 50.3% at discharge. Fifty-two (32.1%) patients developed a persistent complete AVB requiring PPM implantation. PPM implantation was strongly correlated with the presence of preoperative right bundle branch block (RBBB) which was found to be the only independent predictor of PPM implantation (HR 16.5, CI 3.3-82.3, p < 0.001).

Conclusions: LBBB and PPM implantation requirement after TAVI are common occurrences using the self-expanding CoreValve prosthesis. In this large series of consecutive patients, only RBBB was found to be a strong predictor of PPM requirement.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-011-9634-5DOI Listing

Publication Analysis

Top Keywords

ppm implantation
28
conduction disorders
16
implantation
11
ppm
9
incidence rate
8
permanent pacemaker
8
transcatheter aortic
8
aortic valve
8
valve implantation
8
self-expanding corevalve
8

Similar Publications

Background: Transcatheter aortic valve replacement (TAVR) has revolutionized the management of aortic stenosis and has become the standard of care across a broad spectrum of patients with aortic stenosis. However, it is still associated with high incidence of conduction abnormalities, particularly new left bundle branch block (LBBB). Management of these patients remains a challenge.

View Article and Find Full Text PDF

Introduction: Conductive disturbances requiring permanent pacemaker (PPM) implantation remain a major concern after transcatheter aortic valve implantation (TAVI).

Aims: To assess the impact of aortic valve calcium score (AVCS) on conductive disturbances requiring PPM after TAVI.

Methods: All patients who underwent TAVI with accessible AVCS from the preprocedural CT scan report were included in this retrospective single-centre study.

View Article and Find Full Text PDF

Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.

Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.

Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on creating and testing Cobalt-doped zinc oxide nanoparticles as a photocatalyst for degrading the antibiotic ciprofloxacin (CIPF) under visible LED light.
  • It was found that 10% Cobalt-doped ZnO nanoparticles were the most effective, achieving over 99% degradation of CIPF in just 90 minutes, and maintained their efficiency across three cycles of use.
  • The research also optimized the conditions for maximum degradation efficiency using statistical methods and simulated data using Artificial Neural Networks, achieving a strong correlation for the model’s accuracy.
View Article and Find Full Text PDF

Permanent pacemaker (PPM) implantation is the standard of care in patients with complete heart block (CHB) and second-degree type II atrioventricular (AV) block irrespective of patient symptoms when the conduction abnormality is irreversible. CHB generally constitutes a medical emergency that can be fatal if not urgently treated. This is in contrast to first-degree AV block and second-degree type I AV block, which require PPM implantation only in very special circumstances.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!