Determining the monoisotopic peak of a precursor is a first step in interpreting mass spectra, which is basic but non-trivial. The reason is that in the isolation window of a precursor, other peaks interfere with the determination of the monoisotopic peak, leading to wrong mass-to-charge ratio or charge state. Here we propose a method, named pParse, to export the most probable monoisotopic peaks for precursors, including co-eluted precursors. We use the relationship between the position of the highest peak and the mass of the first peak to detect candidate clusters. Then, we extract three features to sort the candidate clusters: (i) the sum of the intensity, (ii) the similarity of the experimental and the theoretical isotopic distribution, and (iii) the similarity of elution profiles. We showed that the recall of pParse, MaxQuant, and BioWorks was 98-98.8%, 0.5-17%, and 1.8-36.5% at the same precision, respectively. About 50% of tandem mass spectra are triggered by multiple precursors which are difficult to identify. Then we design a new scoring function to identify the co-eluted precursors. About 26% of all identified peptides were exclusively from co-eluted peptides. Therefore, accurately determining monoisotopic peaks, including co-eluted precursors, can greatly increase peptide identification rate.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pmic.201100081DOI Listing

Publication Analysis

Top Keywords

monoisotopic peaks
12
mass spectra
12
co-eluted precursors
12
determination monoisotopic
8
determining monoisotopic
8
monoisotopic peak
8
including co-eluted
8
candidate clusters
8
monoisotopic
5
precursors
5

Similar Publications

Lipidomics is a well-established field, enabled by modern liquid chromatography mass spectrometry (LC-MS) technology, rapidly generating large amounts of data. Lipid extracts derived from biological samples are complex, and most spectral features in LC-MS lipidomics data sets remain unidentified. In-depth analyses of commercial triacylglycerol, diacylglycerol, and cholesterol ester standards revealed the expected ammoniated and sodiated ions as well as five additional unidentified higher mass peaks with relatively high intensities.

View Article and Find Full Text PDF
Article Synopsis
  • - Mass spectrometry in chemoproteomics aims to directly identify where small molecules bind to target proteins, but it faces challenges like low protein abundance and difficulties in identifying modification sites with standard software.
  • - Researchers explored BODIPY FL azide as a labeling reagent, utilizing its unique boron isotopes to develop a method that improves the detection of labeled peptides through a specific intensity ratio and mass defect filtering.
  • - The study showed that using BODIPY for labeling not only increased peptide identification from complex samples but also offered a distinct isotopic signature, which could be useful for both UV and fluorescence detection methods.
View Article and Find Full Text PDF

The aim of deconvolution of top-down mass spectra is to recognize monoisotopic peaks from the experimental envelopes in raw mass spectra. So accurate assessment of similarity between theoretical and experimental envelopes is a critical step in mass spectra data deconvolution. Existing evaluation methods primarily rely on intensity differences and / similarity, potentially lacking a comprehensive assessment.

View Article and Find Full Text PDF

Traditionally, mass spectrometry (MS) output is the ion abundance plotted versus the ionic mass-to-charge ratio /. While employing only commercially available equipment, Charge Determination Analysis (CHARDA) adds a third dimension to MS, estimating for individual peaks their charge states starting from = 1 and color coding in / spectra. CHARDA combines the analysis of ion signal decay rates in the time-domain data (transients) in Fourier transform (FT) MS with the interrogation of mass defects (fractional mass) of biopolymers.

View Article and Find Full Text PDF

Spectral Quality Assessment Strategy Based on the C-Isotopic Pattern for the Fourier Transform Ion Cyclotron Resonance Mass Spectra of Dissolved Organic Matter.

J Am Soc Mass Spectrom

August 2023

Hubei Key Laboratory of Yangtze River Basin Environmental Aquatic Science, School of Environmental Studies, China University of Geosciences, Wuhan 430078, China.

The interpretation of data and optimization spectral acquisition of dissolved organic matter (DOM) by ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) have been challenging due to the varied instrument performances among laboratories and the complex chemical characteristics of DOM. However, a universal spectral optimization strategy for FT-ICR MS spectra is still unavailable. The results of this study showed that the number, intensity, and resolving power of all assigned peaks increased with the ion accumulation time (IAT) and DOM concentrations within a reasonable range.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!