Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This article presents a novel method for bone segmentation from three-dimensional (3-D) ultrasound images that derives intensity-invariant 3-D local image phase measures that are then employed for extracting ridge-like features similar to those that occur at soft tissue/bone interfaces. The main contributions in this article include: (1) the extension of our previously proposed phase-symmetry-based bone surface extraction from two-dimensional (2-D) to 3-D images using 3-D Log-Gabor filters; (2) the design of a new framework for accuracy evaluation based on using computed tomography as a gold standard that allows the assessment of surface localization accuracy across the entire 3-D surface; (3) the quantitative validation of accuracy of our 3-D phase-processing approach on both intact and fractured bone surfaces using phantoms and ex vivo 3-D ultrasound scans; and (4) the qualitative validation obtained by scanning emergency room patients with distal radius and pelvis fractures. We show a 41% improvement in surface localization error over the previous 2-D phase symmetry method. The results demonstrate clearly visible segmentations of bone surfaces with a localization accuracy of <0.6 mm and mean errors in estimating fracture displacements below 0.6 mm. The results show that the proposed method is successful even for situations when the bone surface response is weak due to shadowing from muscle and fascia interfaces above the bone, which is a situation where the 2-D method fails.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultrasmedbio.2011.10.009 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!