AI Article Synopsis

  • This study performed a meta-analysis of dual time point FDG-PET in diagnosing pulmonary nodules, aggregating data from ten relevant articles.
  • Summary findings showed a sensitivity of 85% and specificity of 77%, indicating the test's effectiveness but also significant variability in results.
  • The research suggests that dual time point FDG-PET is comparable to single time point FDG-PET, although the expected advantages of the dual approach may be limited due to overlapping characteristics of benign and malignant nodules and lack of clear diagnostic criteria.

Article Abstract

Rationale And Objective: Perform a comprehensive meta-analysis evaluating the diagnostic performance of dual time point deoxy-2-[(18)F]fluoro-D-glucose positron emission tomography (FDG-PET) in the diagnosis of pulmonary nodules.

Materials And Methods: MEDLINE, EMBASE, and PUBMED were queried between January 2000 and January 2011. Studies were included if they: 1) used dual time point FDG-PET as a diagnostic test for pulmonary nodules, 2) used pathology or clinical follow-up as the reference standard, and 3) reported absolute number of true-positive (TP), true-negative (TN), false-positive (FP), and false-negative (FN) results or stated sufficient data to derive these values. Summary sensitivity (SN), summary specificity (SP), positive and negative likelihood ratios (LR+) and (LR-), and diagnostic odds ratio were calculated. Heterogeneity of the results was assessed using Forest plots and the value of inconsistency index (I(2)).

Results: Inclusion criteria were fulfilled by 10 articles with a total of 816 patients and 890 pulmonary nodules. The summary sensitivity was 85% (82%-89% at 95% confidence interval [CI]) and summary specificity was 77% (CI: 72%-81%), with a LR+ of 2.7 (CI: 1.4-5.2) and a LR- of 0.26 (CI: 0.14-0.49). Diagnostic odds ratio was 11 (CI: 3.8-32.2). Significant heterogeneity was found in the sensitivity (I(2) = 77%) and specificity (90.3%).

Conclusion: Dual time point FDG-PET demonstrates similar sensitivity and specificity to single time point FDG-PET in the diagnosis of pulmonary nodules. The additive value of the dual time point FDG-PET is questionable, primarily because of the significant overlap of benign and malignant nodule FDG-PET characteristics and lack of consensus criteria for quantitative thresholds to define nodules as malignant.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2011.10.009DOI Listing

Publication Analysis

Top Keywords

time point
20
pulmonary nodules
16
dual time
16
point fdg-pet
16
diagnosis pulmonary
12
diagnostic performance
8
fdg-pet diagnosis
8
summary sensitivity
8
summary specificity
8
diagnostic odds
8

Similar Publications

Objective: This study aims to evaluate the potential association of perioperative hearing outcomes with frailty by Modified 5-Item Frailty Index (mFI-5).

Design: Retrospective cross-sectional study.

Setting: Single-institutional study conducted at a tertiary care hospital between January 2018 and January 2022.

View Article and Find Full Text PDF

The ARCR_Pred study was initiated to document and predict the safety and effectiveness of arthroscopic rotator cuff repair (ARCR) in a representative Swiss patient cohort. In the present manuscript, we aimed to describe the overall and baseline characteristics of the study, report on functional outcome data and explore case-mix adjustment and differences between public and private hospitals. Between June 2020 and November 2021, primary ARCR patients were prospectively enrolled in a multicenter cohort across 18 Swiss and one German orthopedic center.

View Article and Find Full Text PDF

In this comprehensive analysis of Chile's air quality dynamics spanning 2016 to 2021, the utilization of data from the National Air Quality Information System (SINCA) and its network of monitoring stations was undertaken. Quintero, Puchuncaví, and Coyhaique were the focal points of this study, with the primary objective being the construction of predictive models for sulfur dioxide (SO2), fine particulate matter (PM2.5), and coarse particulate matter (PM10).

View Article and Find Full Text PDF

Deciphering the Energy Transfer Mechanism Across Metal Halide Perovskite-Phthalocyanine Interfaces.

Adv Sci (Weinh)

January 2025

Institute of Molecular Science, University of Valencia, c/Catedrático José Beltrán Martínez 2, Paterna, 46980, Valencia, Spain.

Energy transfer processes in nanohybrids are at the focal point of conceptualizing, designing, and realizing novel energy-harvesting systems featuring nanocrystals that absorb photons and transfer their energy unidirectionally to surface-immobilized functional dyes. Importantly, the functionality of these dyes defines the ultimate application. Herein, CsPbBr perovskite nanocrystals (NCs) are interfaced with zinc phthalocyanine (ZnPc) dyes featuring carboxylic acid.

View Article and Find Full Text PDF

is a Gram-positive bacterium that is responsible for severe nosocomial infections. The rise of multidrug-resistant strains, which can pose significant health threats, prompts the development of new treatment interventions, and much attention has been directed at the development of prophylactic and therapeutic vaccination strategies. Capsular polysaccharides (CPs) are key protective elements of the cell wall and have been proposed as promising candidate antigens.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!