A quartz crystal microbalance-based sensor system coated with functional polymers for SO2 and NO2 detection.

J Nanosci Nanotechnol

Center for Functional Nano Fine Chemicals and School of Applied Chemical Engineering, Chonnam National University, Gwangju 500-757, Korea.

Published: August 2011

In this work, a quartz crystal microbalance (QCM)-based adsorption sensor system with high sensitivity, selectivity, and reproducibility is designed and fabricated. The functional polymers such as polypyrrole, poly(3,4-ethylenedioxythiophene) (PEDOT), and polystyrene are coated on 8 MHz AT-cut quartz crystal surfaces as sensing materials for SO2 and NO2. All sensing materials on the QCM surface are characterized experimentally by SEM and AFM. The frequency shifts of the QCM by adsorption and desorption of gases are measured and analyzed to assess the practical applicability of the sensor system. The overall results show that the QCM coated with polypyrrole is highly selective for SO2 gas and that coated with PEDOT is for NO2. It is proven that the QCM-based adsorption sensor system is possible for monitoring SO2 and NO2 gases in the mixture of ppm level.

Download full-text PDF

Source
http://dx.doi.org/10.1166/jnn.2011.4790DOI Listing

Publication Analysis

Top Keywords

sensor system
16
quartz crystal
12
so2 no2
12
functional polymers
8
qcm-based adsorption
8
adsorption sensor
8
sensing materials
8
crystal microbalance-based
4
sensor
4
microbalance-based sensor
4

Similar Publications

Carbon nanomaterials, particularly carbon nanotubes (CNTs), are widely used as reinforcing fillers in rubber composites for advanced mechanical and electrical applications. However, the influence of rubber functionality and its interactions with CNTs remains underexplored. This study investigates electroactive elastomeric composites fabricated with CNTs in two common diene rubbers: natural rubber (NR) and acrylonitrile-butadiene rubber (NBR), each with distinct functionalities.

View Article and Find Full Text PDF

This paper deals with a "digital twin" (DT) approach for processing, reprocessing, and scrapping (P/R/S) technology running on a modular production system (MPS) assisted by a mobile cyber-physical robotic system (MCPRS). The main hardware architecture consists of four line-shaped workstations (WSs), a wheeled mobile robot (WMR) equipped with a robotic manipulator (RM) and a mobile visual servoing system (MVSS) mounted on the end effector. The system architecture integrates a hierarchical control system where each of the four WSs, in the MPS, is controlled by a Programable Logic Controller (PLC), all connected via Profibus DP to a central PLC.

View Article and Find Full Text PDF

A Feature-Enhanced Small Object Detection Algorithm Based on Attention Mechanism.

Sensors (Basel)

January 2025

School of Artificial Intelligence and Computer Science, Jiangnan University, Wuxi 214122, China.

With the rapid development of AI algorithms and computational power, object recognition based on deep learning frameworks has become a major research direction in computer vision. UAVs equipped with object detection systems are increasingly used in fields like smart transportation, disaster warning, and emergency rescue. However, due to factors such as the environment, lighting, altitude, and angle, UAV images face challenges like small object sizes, high object density, and significant background interference, making object detection tasks difficult.

View Article and Find Full Text PDF

Diagnosis of Reverse-Connection Defects in High-Voltage Cable Cross-Bonded Grounding System Based on ARO-SVM.

Sensors (Basel)

January 2025

Hubei Key Laboratory of Power Equipment & System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China.

High-voltage (HV) cables are increasingly used in urban power grids, and their safe operation is critical to grid stability. Previous studies have analyzed various defects, including the open circuit in the sheath loop, the flooding in the cross-bonded link box, and the sheath grounding fault. However, there is a paucity of research on the defect of the reverse direction between the inner core and the outer shield of the coaxial cable.

View Article and Find Full Text PDF

Mid-infrared spectral analysis has long been recognized as the most accurate noninvasive blood glucose measurement method, yet no practical compact mid-infrared blood glucose sensor has ever passed the accuracy benchmark set by the USA Food and Drug Administration (FDA): to substitute for the finger-pricking glucometers in the market, a new sensor must first show that 95% of their glucose measurements have errors below 15% of these glucometers. Although recent innovative exploitations of the well-established Fourier-transform infrared (FTIR) spectroscopy have reached such FDA accuracy benchmarks, an FTIR spectrometer is too bulky. The advancements of quantum cascade lasers (QCLs) can lead to FTIR spectrometers of reduced size, but compact QCL-based noninvasive blood glucose sensors are not yet available.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!