A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

New insight into visual function with aspherical intraocular lenses (IOLs): Tecnis ZCB00 and Acrysof SN60WF. | LitMetric

In this study, we investigated the visual performance of two aspherical intraocular lenses (IOLs), Tecnis ZCB00 and Acrysof SN60WF, by measuring high-order aberration, visual evoked potentials (VEP), retinal sensitivity, and fixation stability by MP-1 microperimetry and contrast sensitivity values. Twenty-two patients with age-related cataract were randomly allocated to either the Tecnis or the Acrysof group. All measurements were taken from patients of both groups 2 months postoperatively. Statistical analysis was performed with Student's t test, where P-values < 0.05 were considered significant. Results were not statistically significant with regard to high-order aberration, VEP, retinal sensitivity, and fixation stability. However, the contrast sensitivity values varied significantly between Tecnis ZCB00 and Acrysof SN60WF, with Tecnis ZCB00 performing better. The anterior aspherical surface design of the Tecnis IOL indicated better mesopic contrast sensitivity at mediate and high frequencies, ensuring a better quality of vision after cataract surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10792-011-9471-7DOI Listing

Publication Analysis

Top Keywords

aspherical intraocular
8
intraocular lenses
8
lenses iols
8
iols tecnis
8
tecnis zcb00
8
zcb00 acrysof
8
acrysof sn60wf
8
insight visual
4
visual function
4
function aspherical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!