A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surfactant protein A and albumin in particles in exhaled air. | LitMetric

Surfactant protein A and albumin in particles in exhaled air.

Respir Med

Occupational and Environmental Medicine, Sahlgrenska Academy, University of Gothenburg, Box 414, 405 30 Göteborg, Sweden.

Published: February 2012

In this study we test the hypothesis that endogenous particles in exhaled air (PEx), non-invasively sampled from lower airways, are well suited for the analysis of respiratory tract lining fluid (RTLF) proteins, i.e., surfactant protein A (SP-A) and albumin. Ten healthy volunteers were included in the study and participated in two sampling sessions. Blood, exhaled breath condensate (EBC) and PEx were collected at each session. 100 L of breath were collected for each exhaled sample. Serum and exhaled samples were analyzed for SP-A using an in-house ELISA. Albumin was analyzed in exhaled samples using a commercial ELISA kit. SP-A detection rates were 100%, 21%, and 89% for PEx, EBC and serum, respectively. Albumin was detected in PEx, but not in EBC. SP-A measurements in PEx showed good repeatability with an intra-individual coefficient of variation of 13%. Both SP-A and albumin showed significant correlation to mass of PEx (r(s) = 0.93, p < 0.001 and r(s) = 0.86, p = 0.003, respectively). Sampling and analysis of PEx is a valid non-invasive method to monitor RTLF proteins sampled from the lower respiratory tract, as demonstrated here by example of SP-A and albumin analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.rmed.2011.10.008DOI Listing

Publication Analysis

Top Keywords

sp-a albumin
12
surfactant protein
8
particles exhaled
8
exhaled air
8
sampled lower
8
respiratory tract
8
rtlf proteins
8
exhaled samples
8
pex ebc
8
pex
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!