A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Geometrical uncertainty margins in 3D conformal radiotherapy in the pediatric age group. | LitMetric

Purpose: To evaluate set-up variation of pediatric patients undergoing 3D conformal radiotherapy (3DCRT) using electronic portal image device (EPID), in an effort to evaluate the adequacy of the planning target volume (PTV) margin employed for the 3DCRT treatment of pediatric patients.

Materials And Methods: Set-up data was collected from 48 pediatric patients treated with 3DCRTfor head and neck (31 patients), abdomino-pelvic (9 patients) and chest (8 patients) sites during the period between September 2008 and February 2009. A total of 358 images obtained by EPID were analyzed. The mean (M) and standard deviation (SD) for systematic and random errors were calculated and the results were analyzed.

Results: All images were studied in anterior and lateral portals. The systematic errors along longitudinal, lateral and vertical directions in all patients showed an M equal to 1.9, 1.6, and 1.6mm with SD of 1.8, 1.4, and 1.8mm, respectively; (head and neck cases: M equal to 1.5, 1.2, and 1.6mm with SD 1.4, 1.2, and 1.8mm; chest cases: M equal to 2.5, 1.8, and 0.8mm with SD 2.7, 1.7, and 1.2mm, abdomino-pelvic cases: M equal to 2.9, 2.8 and 2.3mm with SD 1.6, 1.2, and 2.3mm). Similarly, the random errors for all patients showed SD of 1.9, 1.6, and 1.8mm, respectively (head and neck cases: SD 1.7, 1.3, and 1.5mm; chest cases: SD 1.2, 1.9, and 2.5mm; abdomino-pelvic cases SD 2.5, 2, and 2.4mm, respectively). Using Van Herk's formula the suggested (PTV) margin around the clinical target volume (CTV) of 5.5mm appears to be adequate.

Conclusion: The ranges of set-up errors are site specific and depends on many factors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jnci.2011.09.001DOI Listing

Publication Analysis

Top Keywords

head neck
12
cases equal
12
conformal radiotherapy
8
pediatric patients
8
target volume
8
ptv margin
8
random errors
8
equal 16mm
8
16mm 18mm
8
18mm head
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!