Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Electrospray ionisation (ESI) is a selective process and, for similar sized analytes, the intrinsic properties of the molecules affect the ionisation process and their response. This research sets out to determine the effect of some of these properties in peptides: peptide polarity and the presence of arginine at positions 1 and 4 in the amino acid sequence on the ESI response. Six peptides; molecular mass ranges 1.3-1.6 kDa; substance P (SP) and glutamate fibrinopeptide (GFP) and 3.2-3.7 kDa; calcitonin gene-related peptide (CGRP), vasoactive intestinal peptide (VIP), glucagon-like peptide 1 (GLP1) and defensin human neutropeptide 2 (DHNP2), were investigated. We have demonstrated that in positive ESI, for similar sized peptides and the same charge state, the responsiveness is in the order: Peptides with N or C terminal arginine > most non-polar peptides > least non-polar peptides. Therefore, arginine at the terminal position is a source of selectivity. Data from matrix-assisted laser desorption ionisation (MALDI) analysis supports that of the ESI experiments: Peptides with a terminal arginine residue generated higher signal intensities. Our observations extend our understanding of the ESI process and provide a rational approach to optimising sensitivity of electrospray conditions where a narrow mass range of peptides are poorly chromatographically resolved. This information will provide for a more effective method development process, especially during label-free quantitative determination of peptides extracted in solution.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/rcm.5270 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!