Reliability of a high-intensity endurance cycling test.

Int J Sports Med

Leeds Metropolitan University, Carnegie Research Institute, Carnegie Faculty, Leeds, United Kingdom.

Published: January 2012

This study assessed the reproducibility of performance and selected metabolic variables during a variable high-intensity endurance cycling test. 8 trained male cyclists (age: 35.9 ± 7.7 years, maximal oxygen uptake: 54.3 ± 3.9 mL·kg - 1·min - 1) completed 4 high-intensity cycling tests, performed in consecutive weeks. The protocol comprised: 20 min of progressive incremental exercise, where the power output was increased by 5% maximal workload (Wmax) every 5 min from 70% Wmax to 85% Wmax; ten 90 s bouts at 90% Wmax, separated by 180 s at 55% Wmax; 90% Wmax until volitional exhaustion. Blood samples were drawn and heart rate was monitored throughout the protocol. There was no significant order effect between trials for time to exhaustion (mean: 4 113.0 ± 60.8 s) or total distance covered (mean: 4 6126.2 ± 1 968.7 m). Total time to exhaustion and total distance covered showed very high reliability with a mean coefficient of variation (CV) of 1.6% (95% Confidence Intervals (CI) 0.0 ± 124.3 s) and CV of 2.2% (95% CI 0.0 ± 1904.9 m), respectively. Variability in plasma glucose concentrations across the time points was very small (CV 0.46-4.3%, mean 95% CI 0.0 ± 0.33 to 0.0 ± 0.94 mmol·L - 1). Plasma lactate concentrations showed no test order effect. The reliability of performance and metabolic variables makes this protocol a valid test to evaluate nutritional interventions in endurance cycling.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0031-1284340DOI Listing

Publication Analysis

Top Keywords

endurance cycling
12
high-intensity endurance
8
cycling test
8
metabolic variables
8
90% wmax
8
time exhaustion
8
total distance
8
distance covered
8
wmax
6
reliability high-intensity
4

Similar Publications

Nonlocalized Conductive Paths Construction and In-depth Mechanism Analysis for the Robust Resistive Switching in Halide Perovskites.

Nano Lett

January 2025

School of Materials Science and Engineering, State Key Laboratory of Structural Analysis, Optimization and CAE Software for Industrial Equipment, National Engineering Research Center for Advanced Polymer Processing Technology, Zhengzhou University, Zhengzhou 450001, China.

The conductive paths (CPs) established by defects in halide perovskites (HPs) tend to be disrupted under external influences, leading to deterioration of their RRAM performances. Here we propose an effective strategy to enhance the CPs in HP RRAMs by doping Ag to partially substitute Pb in MAPbI, which facilitates the nonlocalized growth of Ag CPs and thereby improves the stability of CPs. The optimal doped device demonstrates excellent RRAM performances including high ON/OFF ratios (>10), long retention (>10 s), large endurance (>10 cycles), uniform parameters, and excellent yield.

View Article and Find Full Text PDF

Purpose: To examine sex-based differences in substrate oxidation, postprandial metabolism, and performance in response to 24-hour manipulations in energy availability (EA), induced by manipulations to energy intake (EI) or exercise energy expenditure (EEE).

Methods: In a Latin Square design, 20 endurance athletes (10 females using monophasic oral contraceptives and 10 males) undertook five trials, each comprising three consecutive days. Day one was a standardized period of high EA; EA was then manipulated on day two; post-intervention testing occurred on day three.

View Article and Find Full Text PDF

Curcumin is known for its potential health benefits; however, the evidence remains inconclusive regarding its necessity as a supplement for athletes during the preparatory phase of training. This study aimed to assess the effect of 6-week curcumin supplementation at a dose of 2g/day on selected inflammatory markers, blood count, and brain-derived neurotropic factor (BDNF) levels in middle-aged amateur long-distance runners during the preparatory period of a macrocycle. Thirty runners were randomly assigned to either a curcumin-supplemented group (CUR, n = 15) or a placebo group (PLA, n = 15).

View Article and Find Full Text PDF

Fluid Intake and Hydration Responses to Mass Participation Gravel Cycling.

Int J Exerc Sci

December 2024

Metabolism and Applied Physiology Laboratory, Department of Kinesiology, California State University, San Marcos, San Marcos, USA.

Gravel cycling is a relatively new cycling discipline, with the Union Cycliste Internationale (UCI) hosting their first World Championships in 2022. Gravel races combine features of road racing, cyclocross, and mountain biking, including terrain of varying technical difficulty, long distances, substantial elevation gain, obstacles, and limited opportunities to stop for in-race nutrition. This study assessed hydration responses to gravel races of three different distances.

View Article and Find Full Text PDF

Examining Changes in Pain Sensitivity Following 8 Minutes of Cycling at Varying Exercise Intensities.

Int J Exerc Sci

December 2024

Rehabilitation and Modulation of Pain (RAMP) Lab, Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, USA.

This study assessed the effect of an eight-minute cycling intervention using varying intensities on exercise-induced hypoalgesia (EIH). The main objective of this study was to examine the effect of varying intensities on pressure pain threshold (PPT) and heat pain threshold (HPT) at the thigh and forearm, tested pre- and post-cycling intervention. Healthy male participants ( = 16) performed a graded exercise test on a cycle ergometer to establish their peak power output (PPO).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!