A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Interlaboratory round robin on cantilever calibration for AFM force spectroscopy. | LitMetric

AI Article Synopsis

  • Single-molecule force spectroscopy using Atomic Force Microscopes (AFMs) depends on accurate cantilever spring constant measurements, making a solid calibration protocol crucial.
  • This study assessed the effectiveness of the thermal noise and Sader methods across eight labs, concluding both can determine spring constants well, with the Sader method being more accurate.
  • The research emphasizes the necessity of precise cantilever calibration, as inaccuracies can lead to significant errors in biological force spectroscopy results, highlighting the establishment of a reliable calibration protocol.

Article Abstract

Single-molecule force spectroscopy studies performed by Atomic Force Microscopes (AFMs) strongly rely on accurately determined cantilever spring constants. Hence, to calibrate cantilevers, a reliable calibration protocol is essential. Although the thermal noise method and the direct Sader method are frequently used for cantilever calibration, there is no consensus on the optimal calibration of soft and V-shaped cantilevers, especially those used in force spectroscopy. Therefore, in this study we aimed at establishing a commonly accepted approach to accurately calibrate compliant and V-shaped cantilevers. In a round robin experiment involving eight different laboratories we compared the thermal noise and the Sader method on ten commercial and custom-built AFMs. We found that spring constants of both rectangular and V-shaped cantilevers can accurately be determined with both methods, although the Sader method proved to be superior. Furthermore, we observed that simultaneous application of both methods on an AFM proved an accurate consistency check of the instrument and thus provides optimal and highly reproducible calibration. To illustrate the importance of optimal calibration, we show that for biological force spectroscopy studies, an erroneously calibrated cantilever can significantly affect the derived (bio)physical parameters. Taken together, our findings demonstrated that with the pre-established protocol described reliable spring constants can be obtained for different types of cantilevers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2011.09.012DOI Listing

Publication Analysis

Top Keywords

force spectroscopy
16
spring constants
12
sader method
12
v-shaped cantilevers
12
round robin
8
cantilever calibration
8
spectroscopy studies
8
accurately determined
8
thermal noise
8
optimal calibration
8