Aim: To compare high resolution colonoscopy (Olympus Lucera) with a megapixel high resolution system (Pentax HiLine) as an in-service evaluation.
Methods: Polyp detection rates and measures of performance were collected for 269 colonoscopy procedures. Five colonoscopists conducted the study over a three month period, as part of the United Kingdom bowel cancer screening program.
Results: There were no differences in procedure duration (χ² P = 0.98), caecal intubation rates (χ² P = 0.67), or depth of sedation (χ² P = 0.64). Mild discomfort was more common in the Pentax group (χ² P = 0.036). Adenoma detection rate was significantly higher in the Pentax group (χ² test for trend P = 0.01). Most of the extra polyps detected were flat or sessile adenomas.
Conclusion: Megapixel definition colonoscopes improve adenoma detection without compromising other measures of endoscope performance. Increased polyp detection rates may improve future outcomes in bowel cancer screening programs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3214706 | PMC |
http://dx.doi.org/10.3748/wjg.v17.i38.4308 | DOI Listing |
Arch Gynecol Obstet
January 2025
Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, No. 6 Shuangyong Road, Nanning, 530021, Guangxi, China.
Purpose: This case report aims to present a rare case of endometrial carcinosarcoma, a highly malignant tumor with a poor prognosis. The primary objective is to describe this unique case's clinical presentation, multimodal magnetic resonance imaging (MRI) features, typical histopathological characteristics and surgical treatment.
Methods: A detailed analysis of the patient's medical history, preoperative imaging evaluation, and treatment approach was conducted.
JACC Clin Electrophysiol
December 2024
Physiology, Amsterdam Cardiovascular Sciences, Heart Failure, and Arrhythmias, Amsterdam University Medical Center, location Vrije Universiteit Amsterdam, Amsterdam, the Netherlands. Electronic address:
Background: Atrial fibrillation (AF) persistence is associated with molecular remodeling that fuels electrical conduction abnormalities in atrial tissue. Previous research revealed DNA damage as a molecular driver of AF.
Objectives: This study sought to explore the diagnostic value of DNA damage in atrial tissue and blood samples as an indicator of the prevalence of electrical conduction abnormalities and stage of AF.
J Clin Med
January 2025
Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok 10400, Thailand.
Injuries involving the Atlas (C1) and Axis (C2) vertebrae of the cervical spine present significant clinical challenges due to their complex anatomy and potential for severe neurological impairment. Traditional imaging methods often lack the detailed visualization required for precise surgical planning. This study aimed to develop high-resolution 3D models of the C1 and C2 vertebrae to perform a comprehensive morphometric analysis, identify gender differences, and assess bilateral symmetry to enhance surgical accuracy.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Pediatric Cardiology, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, University of Health Sciences, Istanbul 34303, Turkey.
: Cardiac magnetic resonance (CMR) plays a central role in the diagnosis and follow-up of acute myocarditis (AM). In this study, we aimed to evaluate baseline and follow-up CMR findings and associated factors in children with AM. : A retrospective analysis of CMR in pediatric patients with clinical presentations suggestive of myocarditis was performed.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Electrical and Electronic Engineering, Yonsei University, Seoul 03722, Republic of Korea.
Video frame interpolation (VFI) is a task that generates intermediate frames from two consecutive frames. Previous studies have employed two main approaches to extract the necessary information from both frames: pixel-level synthesis and flow-based methods. However, when synthesizing high-resolution videos using VFI, each approach has its limitations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!