Right ventricular failure (RVF) after left ventricular assist device (LVAD) placement is associated with increased morbidity and mortality. Echocardiography is a primary imaging method in the assessment of cardiac function; however, visualization of the right-sided heart is often technically difficult in patients with heart failure. We aimed to create a simple and generally applicable scoring system based on "left-sided echocardiographic parameters" to provide complementary information for predicting RVF after LVAD surgery. We reviewed 111 consecutive patients undergoing LVAD surgery from 2007 through 2010. Echocardiograms within 5 days before surgery were analyzed. RVF was defined as an unexpected RV assist devices requirement, nitric oxide inhalation >48 hours, and/or inotropic support >14 days. Thirty-five patients (32%) developed RVF. LV end-diastolic dimension (LVEDD) was smaller, LV ejection fraction was greater, and the left atrial diameter/LVEDD ratio was greater (p < 0.05 for all comparisons) in patients with RVF than in those without RVF. An RVF score (LV echocardiographic RVF score) was determined as a sum of points based on receiver operator characteristics analysis: LVEDD >78, 79 to 70, and <70 mm; LV ejection fraction ≤19%, 19% to 33%, and >33%; and left atrial diameter/LVEDD <0.63, 0.63 to 0.68, and >0.68; each variable was associated with 0 and 1 point and 2 points, respectively. LV echocardiographic RVF score ≥3 was associated with RVF with a sensitivity of 88.6% and score ≥5 with a specificity of 80.3%. In conclusion, patients with relatively small LV size, preserved LV contraction, and dilated left atrium were at higher risk for RVF after LVAD surgery. In conclusion, LV echocardiographic RVF score provides a novel tool to predict RVF after LVAD surgery, which does not involve invasive or technically complicated procedures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjcard.2011.08.040 | DOI Listing |
ASAIO J
December 2024
Cleveland Clinic Florida, Heart, Vascular and Thoracic Institute, Advanced Heart Failure Program, Weston, Florida.
We investigated the association of preimplant left ventricular end-diastolic diameter (LVEDD) with outcomes after HeartMate 3 (HM3) left ventricular assist device (LVAD) implantation. Patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) registry who underwent HM3 implantation from August 2014 to February 2023 (n = 834) were analyzed according to preoperative LVEDD: less than or equal to 65 (n = 251), 65-80 (n = 441), and greater than or equal to 80 mm (n = 142). The mean age was 54.
View Article and Find Full Text PDFClin Transplant
January 2025
Department of Cardiovascular Surgery, Başkent University Faculty of Medicine, Ankara, Turkey.
Introduction: End-stage heart failure (ESHF) remains a significant challenge despite optimal treatment, with heart transplantation (HTx) being the gold standard of care. Mechanical circulatory support (MCS) devices such as left ventricular assist devices (LVADs) are increasingly used for temporary or permanent treatment. Psychiatric comorbidities are common in patients with ESHF and may affect treatment outcomes, but the relationship between sociodemographic, clinical, and psychiatric characteristics remains unclear.
View Article and Find Full Text PDFMedicina (Kaunas)
November 2024
Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Carl-Neuberg-Straße 1, 30625 Hannover, Germany.
The use of temporary left ventricular assist devices (tLVADs) for patients suffering from cardiogenic shock (CS) is becoming more common. This study examines the indications and outcomes of microaxial flow pumps (Impella, Abiomed Inc., Danvers, MA, USA) when cannulated through the axillary artery in patients with severe CS, with a particular focus on acute phase reactions and hemolytic responses.
View Article and Find Full Text PDFJ Clin Med
December 2024
Department of Cardiothoracic Surgery, University Medical Center Regensburg, Franz-Josef-Strauß-Allee 11, 93053 Regensburg, Germany.
Ventricular assist devices (VADs) invigorated the management of patients with advanced heart failure, providing a lifeline for patients awaiting transplantation or requiring long-term circulatory support. This article reviews recent advances in VAD technologies, focusing on key areas of progress to overcome existing challenges and the potential for future applications. The reduction or possible elimination of infection-prone components and the evolution to transcutaneous energy transfer systems are two main research fields to reach a new quality of life category for VADs patients.
View Article and Find Full Text PDFJ Clin Med
December 2024
School of Medicine, College of Medicine Nursing and Health Sciences, University of Galway, H91 TK33 Galway, Ireland.
Sacubitril/valsartan is an angiotensin receptor-neprilysin inhibitor (ARNI) drug used to treat patients with heart failure and has shown improvement in outcomes. Different studies reported the use of an ARNI in patients using left ventricular assist devices (LVADs). However, there are limited data on the use of ARNIs in this population.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!