Accuracy and precision for measurements of the mass ratio 30/28 in dinitrogen from air samples and its application to the investigation of N losses from soil by denitrification.

Isotopes Environ Health Stud

a Sektion Bodenforschung, UFZ-Umweltforschungszentrum Leipzig-Halle GmbH , Leipzig , Deutschland.

Published: August 1996

Abstract In the 1950s Hauck introduced a special version of the (15)N dilution technique ((15)N flux method) for the determination of N losses from the soil by denitrification. Although this method is very useful and reliable its application has been rather infrequent up to now. This is mainly due to the need to measure the m/z 30 in addition to the usually measured m/z 28 and 29 for dinitrogen, because the (15)N in the enriched air sample taken from an enclosure (cover box) at the soil surface is nonrandom. The signal from the m/z 30 is very low and difficult to measure with sufficient precision because other species (e.g. NO) also having the m/z 30 often interfere with its measurement. In this study the accuracy and precision of an easy to use CF-IRMS with sample batch operation to measure the ratio 30/28 was investigated. The relative standard deviation (RSD = precision) from natural abundance up to 2 at.% was always <1%. After correction of the mass ratio 30/28 (R30), by means of a formula obtained by linear regression of theoretical R30 against measured R30, the accuracy of the abundance calculated from this corrected R30 was very high. From the achieved precision and assuming a cover box height of 10 cm (headspace volume of 7 1), and a collection time of 2 h, a limit of detection for N(2) losses by denitrification equivalent to 16 g N/ha*d or 6 kg N/ha*a can be estimated. The performance of the (15)N dilution method using the equipment and procedure described is demonstrated by means of results from an incubation experiment with [(15)N]nitrate-amended soils.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10256019608036322DOI Listing

Publication Analysis

Top Keywords

accuracy precision
8
ratio 30/28
8
losses soil
8
soil denitrification
8
precision measurements
4
measurements mass
4
mass ratio
4
30/28 dinitrogen
4
dinitrogen air
4
air samples
4

Similar Publications

Purpose: MR-based FID navigators (FIDnavs) do not require gradient pulses and are attractive for prospective motion correction (PMC) due to short acquisition times and high sampling rates. However, accuracy and precision are limited and depend on a separate calibration measurement. Besides FIDnavs, stationary NMR field probes are also capable of measuring local, motion-induced field changes.

View Article and Find Full Text PDF

Artificial Intelligence-Based Detection and Numbering of Dental Implants on Panoramic Radiographs.

Clin Implant Dent Relat Res

February 2025

SEMRUK Technology Inc., Cumhuriyet Teknokent, Sivas, Turkiye.

Objectives: This study aimed to develop an artificial intelligence (AI)-based deep learning model for the detection and numbering of dental implants in panoramic radiographs. The novelty of this model lies in its ability to both detect and number implants, offering improvements in clinical decision support for dental implantology.

Materials And Methods: A retrospective dataset of 32 585 panoramic radiographs, collected from patients at Sivas Cumhuriyet University between 2014 and 2024, was utilized.

View Article and Find Full Text PDF

CardiacField: computational echocardiography for automated heart function estimation using two-dimensional echocardiography probes.

Eur Heart J Digit Health

January 2025

Department of Cardiovascular Surgery of Zhongshan Hospital, Fudan University, Shanghai 200032, China.

Aims: Accurate heart function estimation is vital for detecting and monitoring cardiovascular diseases. While two-dimensional echocardiography (2DE) is widely accessible and used, it requires specialized training, is prone to inter-observer variability, and lacks comprehensive three-dimensional (3D) information. We introduce CardiacField, a computational echocardiography system using a 2DE probe for precise, automated left ventricular (LV) and right ventricular (RV) ejection fraction (EF) estimations, which is especially easy to use for non-cardiovascular healthcare practitioners.

View Article and Find Full Text PDF

Research on atrial fibrillation diagnosis in electrocardiograms based on CLA-AF model.

Eur Heart J Digit Health

January 2025

Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, No. 88 West Taishan Road, Zhuzhou 412007, Hunan, China.

Aims: The electrocardiogram (ECG) is the primary method for diagnosing atrial fibrillation (AF), but interpreting ECGs can be time-consuming and labour-intensive, which deserves more exploration.

Methods And Results: We collected ECG data from 6590 patients as YY2023, classified as Normal, AF, and Other. Convolutional Neural Network (CNN), bidirectional Long Short-Term Memory (BiLSTM), and Attention construct the AF recognition model CNN BiLSTM Attention-Atrial Fibrillation (CLA-AF).

View Article and Find Full Text PDF

Development and validation of a UV-Vis spectrophotometric method for estimation of total content of chalcone.

MethodsX

June 2025

Observatory of Drug-Herb Interactions, Faculty of Pharmacy, University of Coimbra, Health Science Campus, Azinhaga Santa Comba, Coimbra, Portugal.

In this study, a straightforward spectrophotometric method was developed for quantifying the total content of chalcones in a sample. The method exhibits linearity, accuracy, precision, repeatability, and enables the estimation of total chalcone content in trans-chalcone equivalents for a sample diluted in carbon tetrachloride and added to antimony pentachloride. The analytical wavelength was determined to be 390 nm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!