The effect of static pressure on acoustic emissions including shock-wave emissions from cavitation bubbles in viscous liquids under ultrasound has been studied by numerical simulations in order to investigate the effect of static pressure on dispersion of nano-particles in liquids by ultrasound. The results of the numerical simulations for bubbles of 5 μm in equilibrium radius at 20 kHz have indicated that the optimal static pressure which maximizes the energy of acoustic waves radiated by a bubble per acoustic cycle increases as the acoustic pressure amplitude increases or the viscosity of the solution decreases. It qualitatively agrees with the experimental results by Sauter et al. [Ultrason. Sonochem. 15, 517 (2008)]. In liquids with relatively high viscosity (∼200 mPa s), a bubble collapses more violently than in pure water when the acoustic pressure amplitude is relatively large (∼20 bar). In a mixture of bubbles of different equilibrium radius (3 and 5 μm), the acoustic energy radiated by a 5 μm bubble is much larger than that by a 3 μm bubble due to the interaction with bubbles of different equilibrium radius. The acoustic energy radiated by a 5 μm bubble is substantially increased by the interaction with 3 μm bubbles.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/1.3626130 | DOI Listing |
PLoS One
January 2025
Ltd Project Construction Management Company, Jiangxi Provincial Communications Investment Group Co., Nanchang, China.
The impact of interlayer shear stress on the distribution of earth pressure in cohesive soil is notable, but currently, there lacks a comprehensive theory that integrates this factor in the calculation of active earth pressure. Drawing from the Mohr stress circle specific to clay soils, a formula to calculate interlayer shear stress has been derived. Moreover, a robust model has been formulated to compute the active earth pressure in clay soils, incorporating elements such as interlayer shear stress, effects of displacement, soil arching, and the morphology of the sliding surface.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
Key Laboratory of Impact and Safety Engineering (Ningbo University), Ministry of Education, Ningbo 315211, China.
Obtaining reliable dynamic mechanical properties through experiments is essential for developing and validating constitutive models in material selection and structural design. This study introduces a dynamic tensile method using a modified M-type specimen loaded by a split Hopkinson pressure bar (SHPB). A closed M-type specimen was thus employed.
View Article and Find Full Text PDFJ Pediatr Orthop B
October 2024
Department of General Surgery and Medical Surgical Specialties, Section of Orthopaedics and Traumatology, A.O.U.P. Policlinico Rodolico - San Marco, University of Catania, Catania.
This study evaluated the static, postural, dynamic, and clinical outcomes among five groups of patients: a bilateral CTEV (congenital talipes equinovarus) group treated with tenotomy (n = 14), bilateral CTEV group treated conservatively (n = 6), unilateral CTEV group treated with tenotomy (n = 7), unilateral CTEV group treated conservatively (n = 3), and control group (n = 20). Data were collected through baropodometric examinations and clinical evaluations using Pirani, clubfoot assessment protocol, foot and ankle disability index (FADI), and American Orthopedic Foot and Ankle Society scores. Bilateral CTEV patients treated with tenotomy showed no statistically significant differences compared to healthy controls.
View Article and Find Full Text PDFJ Chiropr Med
December 2024
Department of Physical Therapy, School of Rehabilitation Sciences, Semnan University of Medical Sciences, Semnan, Iran.
Objective: The purpose of the study was to compare the impact of the mobilization techniques and mobilization with movement techniques on static balance in individuals with acute inversion ankle sprain.
Methods: Volunteers with acute inversion ankle sprain ( = 40) were equally and randomly assigned to 2 groups. Participants in intervention group I received the Mulligan mobilization with movement techniques, whereas participants in intervention group II underwent the Maitland mobilization techniques.
Sci Rep
January 2025
Institute for Anatomy und Cell Biology, Department of Medical Cell Biology, Philipps-Universität Marburg, Robert-Koch-Str. 8, 35032, Marburg, Germany.
Maximal isometric contraction time (MICT) is critical for most motor tasks and depends on skeletal muscle blood flow at < 40% of maximal voluntary strength (MVC). Whether limb work positions associated with reduced perfusion pressure and facilitated vessel compression affect MICT is largely unknown. In 14 healthy young men we therefore assessed bilateral handgrip MICT at 15, 20, 30, 40, and 70% of MVC in horizontal forearm positions of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!