In medical ultrasound, fundamental imaging (FI) uses the reflected echoes from the same spectral band as that of the emitted pulse. The transmission frequency determines the trade-off between penetration depth and spatial resolution. Tissue harmonic imaging (THI) employs the second harmonic of the emitted frequency band to construct images. Recently, superharmonic imaging (SHI) has been introduced, which uses the third to the fifth (super) harmonics. The harmonic level is determined by two competing phenomena: nonlinear propagation and frequency dependent attenuation. Thus, the transmission frequency yielding the optimal trade-off between the spatial resolution and the penetration depth differs for THI and SHI. This paper quantitatively compares the concepts of fundamental, second harmonic, and superharmonic echocardiography at their optimal transmission frequencies. Forward propagation is modeled using a 3D-KZK implementation and the iterative nonlinear contrast source (INCS) method. Backpropagation is assumed to be linear. Results show that the fundamental lateral beamwidth is the narrowest at focus, while the superharmonic one is narrower outside the focus. The lateral superharmonic roll-off exceeds the fundamental and second harmonic roll-off. Also, the axial resolution of SHI exceeds that of FI and THI. The far-field pulse-echo superharmonic pressure is lower than that of the fundamental and second harmonic. SHI appears suited for echocardiography and is expected to improve its image quality at the cost of a slight reduction in depth-of-field.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/1.3643815 | DOI Listing |
J Am Chem Soc
December 2024
Center for Nanochemistry, Beijing Science and Engineering Center for Nanocarbons, Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China.
The nonlinear optical response in graphene is finding increasing applications in nanophotonic devices. The activation and enhancement of second harmonic generation (SHG) in graphene, which is generally forbidden in monolayer and AB-stacked bilayer graphene due to their centrosymmetry, is of urgent need for nanophotonic applications. Here, we present a comprehensive study of SHG performance of twisted multilayer graphene structures based on stacking engineering.
View Article and Find Full Text PDFInt J Surg
October 2024
Department of Surgery, Sapienza University of Rome, Rome, Italy.
Background: One of the most important surgical steps during thyroidectomy is the safe ligation of vessels. In fact, it is crucial to avoid postoperative bleeding and nerves' injury. The "clamp and tie" technique was first introduced in the 19th century.
View Article and Find Full Text PDFJ Am Acad Orthop Surg
December 2024
From the Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT (Graesser), the Washington University School of Medicine in St. Louis, Mallinckrodt Institute of Radiology, St. Louis, MO (Parsons), and the Department of Orthopaedic Surgery, Washington University School of Medicine in St. Louis, St. Louis, MO (Olafsen, Dy, and Brogan).
Traumatic peripheral nerve injuries represent a spectrum of conditions and remain challenging to diagnose and prognosticate. High-resolution ultrasonography and magnetic resonance neurography have emerged as useful diagnostic modalities in the evaluation of traumatic peripheral nerve and brachial plexus injuries. Ultrasonography is noninvasive, is able to rapidly interrogate large areas and multiple nerves, allows for a dynamic assessment of nerves and their surrounding anatomy, and is cost-effective.
View Article and Find Full Text PDFJ Voice
December 2024
Department of Music, Faculty of Human Ecology, Universiti Putra Malaysia, 43400 Serdang, Selangor, Malaysia. Electronic address:
Background/objectives: The coronavirus disease (COVID-19) pandemic has significantly impacted global health, with Malaysia reporting over 5 million cases as of May 2024. While symptoms like fatigue and breathlessness are commonly reported among COVID-19 patients, limited research exists on the vocal and pulmonary conditions of individuals with long COVID symptoms. This study aims to assess vocal impairments and pulmonary function differences between long COVID patients and healthy controls, addressing gaps in understanding how long COVID affects vocal and respiratory health.
View Article and Find Full Text PDFJ Voice
December 2024
Neurology Department II, Fuyang People's Hospital, Fuyang, China. Electronic address:
Purpose: Parkinson disease (PD) is a progressive neurodegenerative disease. The aim of this study is to investigate the association between acoustic and cortical brain features in Parkinson's disease patients.
Methods: We recruited 19 (eight females, 11 males) Parkinson's disease patients and 19 (eight females, 11 males) healthy subjects to participate in the experiment.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!