A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A software tool for automatic analysis of selected area diffraction patterns within Digital Micrograph™. | LitMetric

A software tool for automatic analysis of selected area diffraction patterns within Digital Micrograph™.

Ultramicroscopy

Materials Science and Engineering Department, Mail Code 0237, Virginia Tech, Blacksburg, VA 24061, USA.

Published: January 2012

A software package "SADP Tools" is developed as a complementary diffraction pattern analysis tool. The core program, called AutoSADP, is designed to facilitate automated measurements of d-spacing and interplaner angles from TEM selected area diffraction patterns (SADPs) of single crystals. The software uses iterative cross correlations to locate the forward scattered beam position and to find the coordinates of the diffraction spots. The newly developed algorithm is suitable for fully automated analysis and it works well with asymmetric diffraction patterns, off-zone axis patterns, patterns with streaks, and noisy patterns such as Fast Fourier transforms of high-resolution images. The AutoSADP tool runs as a macro for the Digital Micrograph program and can determine d-spacing values and interplanar angles based on the pixel ratio with an accuracy of better than about 2%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2011.09.013DOI Listing

Publication Analysis

Top Keywords

diffraction patterns
12
selected area
8
area diffraction
8
patterns
6
diffraction
5
software tool
4
tool automatic
4
automatic analysis
4
analysis selected
4
patterns digital
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!