Purpose: To simulate and optimize a MR protocol for squamous cell cancer of the head and neck (HNSCC) patients for potential future use in an integrated whole-body MR-PET scanner.

Materials And Methods: On a clinical 3T scanner, which is the basis for a recently introduced fully integrated whole-body MR-PET, 20 patients with untreated HNSCC routinely staged with 18F-FDG PET/CT underwent a dedicated MR protocol for the neck. Moreover, a whole-body Dixon MR-sequence was applied, which is used for attenuation correction on a recently introduced hybrid MR-PET scanner. In a subset of patients volume-interpolated-breathhold (VIBE) T1w-sequences for lungs and liver were added. Total imaging time was analyzed for both groups. The quality of the delineation of the primary tumor (scale 0-3) and the presence or absence of lymph node metastases (scale 1-5) was evaluated for CT, MR, PET/CT and a combination of MR and PET to ensure that the MR-PET fusion does not cause a loss of diagnostic capability. PET was used to identify distant metastases. The PET dataset for simulated MR/PET was based on a segmentation of the CT data into 4 classes according to the approach of the Dixon MR-sequence for MR-PET. Standard of reference was histopathology in 19 cases. In one case no histopathological confirmation of a primary tumor could be achieved.

Results: Mean imaging time was 35:17 min (range: 31:08-42:42 min) for the protocol including sequences for local staging and attenuation correction and 44:17 min (range: 35:44-54:58) for the extended protocol. Although not statistically significant a combination of MR and PET performed better in the delineation of the primary tumor (mean 2.20) compared to CT (mean 1.40), MR (1.95) and PET/CT (2.15) especially in patients with dental implants. PET/CT and combining MR and PET performed slightly better than CT and MR for the assessment of lymph node metastases. Two patients with distant metastases were only identified by PET.

Conclusion: We established a potential MR-protocol to be used for HNSCC patients in a recently introduced MR-PET scanner. The proposed protocol can be performed in an acceptable time frame and did not lead to a loss of diagnostic capability compared to PET/CT.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2011.10.005DOI Listing

Publication Analysis

Top Keywords

attenuation correction
12
primary tumor
12
hnscc patients
8
integrated whole-body
8
whole-body mr-pet
8
dixon mr-sequence
8
mr-pet scanner
8
imaging time
8
delineation primary
8
lymph node
8

Similar Publications

Curcumae Longae Rhizoma (CLRh), Curcumae Radix (CRa), and Curcumae Rhizoma (CRh), derived from the different medicinal parts of the species, are blood-activating analgesics commonly used for promoting blood circulation and relieving pain. Due to their certain similarities in chemical composition and pharmacological effects, these three herbs exhibit a high risk associated with mixing and indiscriminate use. The diverse methods used for distinguishing the medicinal origins are complex, time-consuming, and limited to intraspecific differentiation, which are not suitable for rapid and systematic identification.

View Article and Find Full Text PDF

Background: Central arterial stiffening is associated with brain white matter (WM) damage and gray matter (GM) volume loss in older adults, but little is known about this association from an adult lifespan perspective.

Purpose: To investigate the associations of central arterial stiffness with WM microstructural organization, WM lesion load, cortical thickness, and GM volume in healthy adults across the lifespan.

Study Type: This is a cross-sectional study.

View Article and Find Full Text PDF

Bone marrow transplantation reverses metabolic alterations in multiple sulfatase deficiency: a case series.

Commun Med (Lond)

January 2025

Department of Pediatrics, Division of Blood and Marrow Transplantation, University of Minnesota, Minneapolis, MN, USA.

Background: Multiple sulfatase deficiency (MSD) is an exceptionally rare neurodegenerative disorder due to the absence or deficiency of 17 known cellular sulfatases. The activation of all these cellular sulfatases is dependent on the presence of the formylglycine-generating enzyme, which is encoded by the SUMF1 gene. Disease-causing homozygous or compound heterozygous variants in SUMF1 result in MSD.

View Article and Find Full Text PDF

Diagnostic Accuracy of Low-Dose Myocardial Perfusion Imaging in a Real-World Setting.

J Nucl Cardiol

January 2025

Université de Lorraine, CHRU-Nancy, Department of Nuclear Medicine and Nancyclotep Imaging Platform, F-54000, Nancy, France; Université de Lorraine, INSERM U1254, IADI, F-54000 Nancy, France. Electronic address:

Background: This large-scale study analyzes factors affecting diagnostic accuracy of low-dose myocardial perfusion imaging and correlation with coronary angiography in a real-world practice.

Methods: We compared data extracted from routine reports of (i) low-dose [Tc]sestamibi stress-MPI performed with no attenuation correction and predominantly exercise stress testing and (ii) the corresponding coronary angiography.

Results: We considered 1070 pairs of coronary angiography/stress-MPI results reported by 11 physicians.

View Article and Find Full Text PDF

: Orthognathic surgery is used to restore a correct anatomical and functional relationship between the jaws, with postoperative nasal septal deviation (NSD) being a common complication of Le Fort I osteotomy (LF-IO). The aim of this study was to evaluate the occurrence of NSD after LF-IO and to identify possible risk factors. : Pre- and postoperative cone beam computed tomography (CBCT) scans from 2018 to 2023 of 102 patients after LF-IO were analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!