Screening for emphysema via exhaled volatile organic compounds.

J Breath Res

Life Science Trace Gas Facility, Molecular and Laser Physics, Institute for Molecules and Materials, Radboud University, Nijmegen, the Netherlands.

Published: December 2011

Chronic obstructive pulmonary disease (COPD)/emphysema risk groups are well defined and screening allows for early identification of disease. The capability of exhaled volatile organic compounds (VOCs) to detect emphysema, as found by computed tomography (CT) in current and former heavy smokers participating in a lung cancer screening trial, was investigated. CT scans, pulmonary function tests and breath sample collections were obtained from 204 subjects. Breath samples were analyzed with a proton-transfer reaction mass spectrometer (PTR-MS) to obtain VOC profiles listed as ions at various mass-to-charge ratios (m/z). Using bootstrapped stepwise forward logistic regression, we identified specific breath profiles as a potential tool for the diagnosis of emphysema, of airflow limitation or gas-exchange impairment. A marker for emphysema was found at m/z 87 (tentatively attributed to 2-methylbutanal). The area under the receiver operating characteristic curve (ROC) of this marker to diagnose emphysema was 0.588 (95% CI 0.453-0.662). Mass-to-charge ratios m/z 52 (most likely chloramine) and m/z 135 (alkyl benzene) were linked to obstructive disease and m/z 122 (most probably alkyl homologs) to an impaired diffusion capacity. ROC areas were 0.646 (95% CI 0.562-0.730) and 0.671 (95% CI 0.524-0.710), respectively. In the screening setting, exhaled VOCs measured by PTR-MS constitute weak markers for emphysema, pulmonary obstruction and impaired diffusion capacity.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1752-7155/5/4/046009DOI Listing

Publication Analysis

Top Keywords

exhaled volatile
8
volatile organic
8
organic compounds
8
mass-to-charge ratios
8
ratios m/z
8
impaired diffusion
8
diffusion capacity
8
emphysema
5
m/z
5
screening
4

Similar Publications

Study on exhaled volatile organic compounds identifying cognitive fatigue induced by N-back task in healthy young adults.

Ecotoxicol Environ Saf

January 2025

National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China; China CDC Key Laboratory of Environment and Population Health, Beijing 100021, China. Electronic address:

Cognitive fatigue in specific occupations may present a risk to personal safety. The study aimed to explore the characteristic volatile organic compounds (VOCs) in exhaled breath in response to cognitive fatigue, to provide a scientific basis for the non-invasive exhaled breath diagnostic techniques for cognitive fatigue assessing. Thirty healthy young adults were recruited and assigned to complete two 1.

View Article and Find Full Text PDF

Short-term modification of breathprint by Elexacaftor/Tezacaftor/Ivacaftor in a paediatric cohort.

J Cyst Fibros

January 2025

INSERM U1151, Institut Necker Enfants Malades, Paris, France; Hôpital Necker Enfants Malades, Centre de Référence Maladies Rares Mucoviscidose et Maladies apparentées, Paris, France; Université Paris-Cité, Paris, France; European Reference Network-Lung. Frankfurt, Germany. Electronic address:

Background: The triple combination Elexacaftor/Tezacaftor/Ivacaftor (ETI) translates into major respiratory improvements in adults; yet current clinical endpoints may prove insufficiently sensitive in young children. We hypothesised that ETI rapidly modifies the lungs' metabolism, resulting in changes in breath composition.

Methods: Eleven children with CF were enrolled in a longitudinal pilot study at the paediatric Necker hospital.

View Article and Find Full Text PDF

Breath analysis is increasingly recognized as a powerful noninvasive diagnostic technique, and a plethora of exhaled volatile biomarkers have been associated with various diseases. However, traditional analytical methodologies are not amenable to high-throughput diagnostic applications at the point of need. An optical spectroscopic technique, surface-enhanced Raman spectroscopy (SERS), mostly used in the research setting for liquid sample analysis, has recently been applied to breath-based diagnostics.

View Article and Find Full Text PDF

A wealth of details regarding an individual's state of health, like a person's respiratory and metabolic functioning, can be studied by analyzing the volatile molecules and atoms in human exhaled breath. Besides, the salinity of seawater is a crucial factor in understanding its characteristics because any variation in the salinity of seawater represents the variations in the hydrological, biological, and chemical distributions. In this paper, a symmetrical one-dimensional phononic structure is theoretically designed using two symmetrical crystals separated with a defective cavity.

View Article and Find Full Text PDF

Breath biopsy is emerging as a rapid and non-invasive diagnostic tool that links exhaled chemical signatures with specific medical conditions. Despite its potential, clinical translation remains limited by the challenge of reliably detecting endogenous, disease-specific biomarkers in breath. Synthetic biomarkers represent an emerging paradigm for precision diagnostics such that they amplify activity-based biochemical signals associated with disease fingerprints.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!