We report an image segmentation and registration method for studying joint morphology and kinematics from in vivo magnetic resonance imaging (MRI) scans and its application to the analysis of foot and ankle joint motion. Using an MRI-compatible positioning device, a foot was scanned in a single neutral and seven other positions ranging from maximum plantar flexion, inversion, and internal rotation to maximum dorsiflexion, eversion, and external rotation. A segmentation method combining graph cuts and level set was developed. In the subsequent registration step, a separate rigid body transformation for each bone was obtained by registering the neutral position dataset to each of the other ones, which produced an accurate description of the motion between them. The segmentation algorithm allowed a user to interactively delineate 14 foot bones in the neutral position volume in less than 30 min total (user and computer processing unit [CPU]) time. Registration to the seven other positions took approximately 10 additional minutes of user time and 5.25 h of CPU time. For validation, our results were compared with those obtained from 3DViewnix, a semiautomatic segmentation program. We achieved excellent agreement, with volume overlap ratios greater than 88% for all bones excluding the intermediate cuneiform and the lesser metatarsals. For the registration of the neutral scan to the seven other positions, the average overlap ratio is 94.25%, while the minimum overlap ratio is 89.49% for the tibia between the neutral position and position 1, which might be due to different fields of view (FOV). To process a single foot in eight positions, our tool requires only minimal user interaction time (less than 30 min total), a level of improvement that has the potential to make joint motion analysis from MRI practical in research and clinical applications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5413119 | PMC |
http://dx.doi.org/10.1115/1.4005175 | DOI Listing |
Arthroplast Today
February 2025
Department of Orthopaedic Surgery, Fiona Stanley Fremantle Hospitals Group, Murdoch, Western Australia, Australia.
Background: Dual mobility (DM) implants in total hip arthroplasty provide excellent range of motion with low dislocation rates. A complication of this design is intraprosthetic dislocation (IPD), where the polyethylene (PE) liner dissociates from the femoral head. In older designs, IPD occurred due to a small head size and late PE wear with head-capture-mechanism failure.
View Article and Find Full Text PDFCureus
December 2024
Clinical Research and Medical Writing, Meril Life Sciences Private Limited, Vapi, IND.
Aim The primary objective of the study was to evaluate the mid-term implant survivability, rate of revisions, and clinical and functional outcomes following patella resurfacing during total knee arthroplasty (TKA) utilizing posterior stabilized (PS) total knee system (TKS). Methods A prospective, single-arm, multi-center, post-marketing surveillance encompassed patients with end-stage primary knee osteoarthritis (OA) or inflammatory arthritis. The time points of the study included baseline, six weeks, six months, one year, and three years post-operatively.
View Article and Find Full Text PDFIowa Orthop J
January 2025
University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA.
Background: Recognizing ACL injuries on the field and in the office can be very challenging in awake and apprehensive patients. Despite high specificity, many published "pivot-shift" techniques have limited acceptance mainly because of unsatisfactory sensitivity. We describe in detail, four specific modifications and provide a critical review of our clinical experiences to empower the new user's readiness to master a novel screening procedure for ACL disruption.
View Article and Find Full Text PDFJ Phys Chem Lett
January 2025
MOE Key Laboratory of Low-grade Energy Utilization Technologies and Systems, CQU-NUS Renewable Energy Materials & Devices Joint Laboratory, School of Energy and Power Engineering, Chongqing University, Chongqing 400044, China.
Hybrid organic-inorganic halide perovskites (HOIPs) have garnered a significant amount of attention due to their exceptional photoelectric conversion efficiency. However, they still face considerable challenges in large-scale applications, primarily due to their instability. One key factor influencing this instability is the lattice softness attributed to the A-site cations.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopedics, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai, 200233, China.
Purpose: Previous studies reported that anterior knee pain (AKP) occurs with an incidence of 32% after opening-wedge high tibial osteotomy (OWHTO). However, the biomechanical effects of this procedure on patellofemoral joints (PFJs) remain unclear. We aimed to quantify the changes in the kinematics and cartilage conditions of the PFJ during stair climbing before and after OWHTO.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!