The objective of this study was to validate the MRI-based joint contact modeling methodology in the radiocarpal joints by comparison of model results with invasive specimen-specific radiocarpal contact measurements from four cadaver experiments. We used a single validation criterion for multiple outcome measures to characterize the utility and overall validity of the modeling approach. For each experiment, a Pressurex film and a Tekscan sensor were sequentially placed into the radiocarpal joints during simulated grasp. Computer models were constructed based on MRI visualization of the cadaver specimens without load. Images were also acquired during the loaded configuration used with the direct experimental measurements. Geometric surface models of the radius, scaphoid and lunate (including cartilage) were constructed from the images acquired without the load. The carpal bone motions from the unloaded state to the loaded state were determined using a series of 3D image registrations. Cartilage thickness was assumed uniform at 1.0 mm with an effective compressive modulus of 4 MPa. Validation was based on experimental versus model contact area, contact force, average contact pressure and peak contact pressure for the radioscaphoid and radiolunate articulations. Contact area was also measured directly from images acquired under load and compared to the experimental and model data. Qualitatively, there was good correspondence between the MRI-based model data and experimental data, with consistent relative size, shape and location of radioscaphoid and radiolunate contact regions. Quantitative data from the model generally compared well with the experimental data for all specimens. Contact area from the MRI-based model was very similar to the contact area measured directly from the images. For all outcome measures except average and peak pressures, at least two specimen models met the validation criteria with respect to experimental measurements for both articulations. Only the model for one specimen met the validation criteria for average and peak pressure of both articulations; however the experimental measures for peak pressure also exhibited high variability. MRI-based modeling can reliably be used for evaluating the contact area and contact force with similar confidence as in currently available experimental techniques. Average contact pressure, and peak contact pressure were more variable from all measurement techniques, and these measures from MRI-based modeling should be used with some caution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3705881PMC
http://dx.doi.org/10.1115/1.4005171DOI Listing

Publication Analysis

Top Keywords

contact area
20
contact pressure
16
contact
14
mri-based modeling
12
validation criteria
12
images acquired
12
radiocarpal joints
8
outcome measures
8
experimental
8
experimental measurements
8

Similar Publications

Enhanced mechanical properties of alkali-activated dolomite dust emulsified asphalt composites.

Sci Rep

December 2024

School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan, China.

The dolomite dust-emulsified asphalt composite (DAC) with excellent mechanical properties was successfully prepared using alkali activation. The effects of different alkali concentrations and emulsified asphalt contents on the mechanical properties of the materials were studied. And the micro-mechanisms of its mechanical performance changes were analyzed through SEM and XRD characterization.

View Article and Find Full Text PDF

Zoonotic transmission of novel Influenza A variant viruses detected in Brazil during 2020 to 2023.

Nat Commun

December 2024

Laboratório de Vírus Respiratórios, Exantemáticos, Enterovírus e Emergências (LVRE), Oswaldo Cruz Foundation, Fiocruz, Rio de Janeiro, Brazil.

Zoonotic infections (swine-human) caused by influenza A viruses (IAVs) have been reported and linked to close contact between these species. Here, we describe eight human IAV variant infections (6 mild and 2 severe cases, including 1 death) detected in Paraná, Brazil, during 2020-2023. Genomes recovered were closely related to Brazilian swIAVs of three major lineages (1 A.

View Article and Find Full Text PDF

Objective: Chronic musculoskeletal pain (CMSP) is frequent in chronic diseases, decreasing the quality of life of these patients. In a survey conducted in Belgium in 2019, chronic pain was named by patients as the main factor of complexity in their lives. The objective of our research was to provide elements to understand why and how CMSP contributes to the complexity of these people's lives.

View Article and Find Full Text PDF

Background: Seeking sexual partners in men who have sex with men (MSM) venues has been regarded as a high-risk behavior for HIV among MSM. Nevertheless, with the implementation of venue-based interventions and the change in the way MSM seek sexual partners, the continued status of MSM venues as the HIV risk factor remains inconclusive. This study endeavors to delve into this ambiguity by examining the MSM sexual contact network (SCN) as a foundation.

View Article and Find Full Text PDF

Introduction: The medial patellofemoral ligament (MPFL) is the main patellar stabilizer in low knee flexion degrees (0-30°). Isolated MPFL reconstruction (MPFLr) is therefore considered the gold standard of surgical procedures for low flexion patellofemoral instabilities (PFIs). Despite excellent clinical results, little is known about the effect of MPFLr on kinematic parameters (KPs) of the patellofemoral joint in vivo.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!