Background And Purpose: Renal cryoablation has gained popularity as a treatment option for localized renal masses. Treatment success is typically defined by the absence of contrast enhancement on follow-up imaging. We investigate the evolution of lesions that demonstrate contrast enhancement on CT after renal cryoablation.

Patients And Methods: Retrospective review of records of laparoscopic and percutaneous cryoablation (LCA and PCA) was performed, identifying records with postoperative radiographic enhancement. Imaging studies were reviewed and radiographic (pre- and post-contrast Hounsfield units, pattern and location of enhancement) and clinical data including follow up were collected.

Results: One hundred and seventy-two cryoablation procedures were analyzed. Of these, 30 (17.4%) showed enhancement on follow-up CT. In 28 cases, contrast enhancement was demonstrated on the first postoperative study. Seven patients underwent salvage treatments. Spontaneous resolution of enhancement was noted in 17 (56.7%) cases. No association was found between enhancement pattern (diffuse/nodular/rim) and resolution. Of lesions enhancing >35 HU, only 14.3% resolved spontaneously. Delayed enhancement (after negative imaging studies) occurred in two patients; both underwent salvage treatments.

Conclusions: Most of the time, contrast-enhancements after cryoablation are evident on the first follow-up imaging study. More than 50% of these resolve spontaneously, and only one of four patients need salvage treatment. Delayed appearance of enhancement after previously negative imaging and highly enhancing lesions (>35 HU) are unlikely to resolve and should be considered suspicious for local recurrence or incomplete ablation. Further investigation is warranted to reach a consensus on a radiographic definition of local recurrence after renal cryoablation.

Download full-text PDF

Source
http://dx.doi.org/10.1089/end.2011.0337DOI Listing

Publication Analysis

Top Keywords

contrast enhancement
16
renal cryoablation
12
enhancement
10
enhancement follow-up
8
follow-up imaging
8
imaging studies
8
patients underwent
8
underwent salvage
8
enhancement negative
8
negative imaging
8

Similar Publications

Background: Multiple myeloma (MM) is an incurable plasma cell malignancy with increasing global incidence. Chimeric antigen receptor (CAR) T-cell therapy targeting BCMA has shown efficacy in relapsed or refractory MM, but it faces resistance due to antigen loss and the tumor microenvironment. Bispecific T-cell engaging (BITE) antibodies also encounter clinical challenges, including short half-lives requiring continuous infusion and potential toxicities.

View Article and Find Full Text PDF

Optimizing hip MRI: enhancing image quality and elevating inter-observer consistency using deep learning-powered reconstruction.

BMC Med Imaging

January 2025

Department of Magnetic Resonance Imaging, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, 450052, China.

Background: Conventional hip joint MRI scans necessitate lengthy scan durations, posing challenges for patient comfort and clinical efficiency. Previously, accelerated imaging techniques were constrained by a trade-off between noise and resolution. Leveraging deep learning-based reconstruction (DLR) holds the potential to mitigate scan time without compromising image quality.

View Article and Find Full Text PDF

Cold stress in winter is one of the most severe abiotic stresses on plant growth and flourishing, and the selection of cold tolerant genotypes is an important strategy to ensure the safety of plant growth and development. Cyclocarya paliurus, a diclinous and versatile tree species originally in subtropical regions, has been introduced and cultivated in the warm temperate zone of China to meet the increasing market demand for its leaf yield. However, information regarding its cold tolerance remains limited.

View Article and Find Full Text PDF

In this work, microalgae-based zinc oxide nanoparticles loaded with electrospun polyvinyl alcohol (PVA)/sodium alginate (SA) nanofibers were fabricated by electro-spinner. PVA/SA fibrous mats were crosslinked by citric acid, which enhanced their thermal stability and swelling behavior. Green-synthesized ZnO NPs were laboratory synthesized and characterized by FTIR, XRD, EDX, SEM, TEM and TGA analyses.

View Article and Find Full Text PDF

Best current practice in the analysis of dynamic contrast enhanced (DCE)-MRI is to employ a voxel-by-voxel model selection from a hierarchy of nested models. This nested model selection (NMS) assumes that the observed time-trace of contrast-agent (CA) concentration within a voxel, corresponds to a singular physiologically nested model. However, admixtures of different models may exist within a voxel's CA time-trace.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!