A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diffusion-weighted whole-body MRI with background body signal suppression: technical improvements at 3.0 T. | LitMetric

Purpose: To improve image quality of diffusion-weighted body magnetic resonance imaging (MRI) with background body signal suppression (DWIBS) at 3.0 T.

Materials And Methods: In 30 patients and eight volunteers, a diffusion-weighted spin-echo echo-planar imaging sequence with short TI inversion recovery (STIR) fat suppression was applied and repeated using slice-selective gradient reversal (SSGR) and/or dual-source parallel radiofrequency (RF) transmission (TX). The quality of diffusion-weighted images and gray scale inverted maximum intensity projections (MIP) were visually assessed by intraindividual comparison with respect to the level of fat suppression and signal homogeneity. Moreover, the contrast between lesions/lymph nodes and background (C(lb)) was analyzed in the MIP reconstructions.

Results: By combining STIR with SSGR, fat suppression was significantly improved (P < 0.001) and C(lb) was increased two times. The use of TX allowed the reduction of acquisition time and improved image quality with regard to signal homogeneity (P < 0.001) and fat suppression (P = 0.005).

Conclusion: DWIBS at 3.0 T can be improved by using SSGR and TX.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.22877DOI Listing

Publication Analysis

Top Keywords

fat suppression
16
mri background
8
background body
8
body signal
8
signal suppression
8
image quality
8
quality diffusion-weighted
8
signal homogeneity
8
suppression
6
diffusion-weighted
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!