Background: The study was conducted to compare 6-month usage of the levonorgestrel-releasing intrauterine device (LNG-IUD) when placed immediately or 3 to 6 weeks after dilation and evacuation (D&E) procedure.
Study Design: We enrolled women undergoing D&E at 15 to 23 weeks of gestation. After completion of the D&E, subjects without contraindications to immediate IUD insertion were randomized to immediate or delayed (3 to 6 weeks later) LNG-IUD insertion. Subjects in the immediate group had the LNG-IUD placed using ultrasound guidance. All subjects returned at 3 to 6 weeks and 8 to 10 weeks after D&E and were contacted by phone at 6 months.
Results: Of the 93 subjects enrolled, 88 were randomized. All 44 subjects (100%) randomized to immediate insertion had successful IUD placement, while only 20 (45.5%) of the 44 subjects randomized to delayed insertion returned for IUD placement, all of which were successful [difference 54.5%, 95% confidence interval (CI) 39.8%-69.3%]. Seventeen (38.6%) participants in each group were lost to follow-up. Of subjects contacted at the 6-month follow-up phone call, 23 of 27 women (85.2%) and 17 of 27 women (62.9%) were utilizing the LNG-IUD in the immediate and delayed groups, respectively (difference 22.2%, 95% CI -0.4% to 44.8%). Intrauterine device expulsion occurred in three subjects (6.8%) and one subject (5.0%) in whom the IUD was placed in the immediate and delayed groups, respectively (p=1.0). No significant adverse events occurred.
Conclusion: Significantly more participants had the LNG-IUD placed in the immediate insertion group compared with the delayed insertion group. Given the low risk of complications, immediate post-D&E insertion of the LNG-IUD should be offered, especially for populations that may have difficulty returning for follow-up.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.contraception.2011.08.002 | DOI Listing |
Cureus
December 2024
Department of Neurosurgery, University of Fukui, Fukui, JPN.
Background Prior to using the exoscope, we speculated that it represented an intermediate tool between a loupe and a microscope and had concerns about its visibility of deep, fine structures. Objective To evaluate the depths of meningioma for which the exoscope was suitable, and to clarify its disadvantages in meningioma resection. Methods Findings of consecutive meningioma surgeries using a 4K three-dimensional (3D) exoscope over a one-year period were evaluated for visibility of the surgical field, comfort of the surgeon's arm posture, the surgeon's head orientation, and perception of the image delay, accounting for the depth of the tumor.
View Article and Find Full Text PDFSci Rep
January 2025
School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350001, China.
This study assessed the accuracy of robotic computer-aided implant surgery (rCAIS) in partially edentulous patients using a standard operation procedure. Patients who underwent implant placement surgeries using the robotic system under a standard operation procedure were recruited. Deviations of dental implants were calculated after superimposition of the preoperative and postoperative cone-beam computed tomography (CBCT) images.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Department of Orthopaedics Surgery, National Children's Medical Center & Children's Hospital of Fudan University, Wanyuan Road 399, Minhang District, Shanghai, 201102, China.
Background: Congenital Pseudarthrosis of the Tibia (CPT) is a rare pediatric condition presenting substantial challenges for orthopedic surgeons. Aiming to achieve bone union, with subsequent complications such as refractures being common. The aim of the present study is to evaluate the results of our intentional cross-union protocol and to compare these outcomes with those obtained from our previously used techniques.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
December 2024
Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
Background: Many unicameral bone cysts (UBC) can be resolved or treated conservatively. Managing persistent symptomatic UBCs in the humerus is particularly challenging. An effective surgical method with low complications is significant for treatment.
View Article and Find Full Text PDFCureus
November 2024
Pain Management, Singapore General Hospital, Singapore, SGP.
Subglottic stenosis poses a rare but life-threatening risk for difficult tracheal intubation. Here, we report a unique case of undiagnosed subglottic stenosis discovered during emergency intubation of an 80-year-old woman with type 2 respiratory failure from infective exacerbation of asthma. A small calibre size 5.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!