Aims: Aortic valve calcification is an actively regulated process with endothelial dysfunction displaying hallmarks of atherosclerosis. C-type natriuretic peptide (CNP) system has been reported to have a role in the pathogenesis of vascular atherosclerosis and to be distinctly downregulated in aortic valve stenosis (AS). Here we studied gene expressions of CNP and is target receptor natriuretic peptide receptor type B (NPR-B) in human aortic valves. Furthermore, we compared gene expression of CNP system in patients with HMG-coenzyme-A reductase (statin) treatment to non-statin-treated patients in AS group.

Methods And Results: With the study population of 108 patients, we characterized expression of CNP and NPR-B in human aortic valves and compared normal control valves (n = 12) with valves obtained from patients with aortic regurgitation (AR, n = 16), AR with fibrosis (AR+fibr., n = 19) and AS (n = 61). By reverse transcription-polymerase chain reaction (RT-PCR), CNP mRNA levels were 89% lower (p = 0.022) in stenotic valves, when compared to AR group. Moreover, the mRNA levels of NPR-B, the target receptor of CNP, were 62% lower (p < 0.001) in stenotic valves when compared to control group and 54% lower (p = 0.002) in stenotic valves, when compared to AR group. There was no statistical significant difference in CNP and NPR-B levels in AS group when the statin-treated patients were compared to untreated patients.

Conclusions: These results show for the first time that the gene expression of anti-atherogenic CNP system did not differ between statin-treated and non-statin-treated patients in AS. The research data supports the results of clinical trials with the same drug class.

Download full-text PDF

Source

Publication Analysis

Top Keywords

valves compared
20
gene expression
12
natriuretic peptide
12
aortic valves
12
cnp system
12
stenotic valves
12
statin treatment
8
expression anti-atherogenic
8
c-type natriuretic
8
valves
8

Similar Publications

Background: Data regarding the effectiveness and safety of endoscopic lung volume reduction with valves (ELVR) in emphysema patients with a very low 6-min walk test (6MWT) are limited. Patients with severe emphysema and very low exercise capacity, as indicated by a 6MWT ≤140 m, are often excluded from clinical studies on ELVR, assuming limited therapeutic benefits and increased complication risk.

Study Designs And Methods: This study utilised data from the Lungenemphysemregister e.

View Article and Find Full Text PDF

Deep-Learning-based Automated Identification of Ventriculoperitoneal-Shunt Valve Models from Skull X-rays.

Clin Neuroradiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich-Heine-University Düsseldorf, Moorenstraße 5, 40225, Düsseldorf, Germany.

Introduction: Ventriculoperitoneal shunts (VPS) are an essential part of the treatment of hydrocephalus, with numerous valve models available with different ways of indicating pressure levels. The model types often need to be identified on X‑rays to assess pressure levels using a matching template. Artificial intelligence (AI), in particular deep learning, is ideally suited to automate repetitive tasks such as identifying different VPS valve models.

View Article and Find Full Text PDF

Aims: To evaluate the association between transcatheter edge-to-edge repair (TEER) and outcomes in patients with significant mitral regurgitation (MR) following acute myocardial infarction (MI), focusing on the aetiology of acute post-MI MR in high-risk surgical patients.

Methods And Results: The International Registry of MitraClip in Acute Mitral Regurgitation following Acute Myocardial Infarction (IREMMI) includes 187 patients with severe MR post-MI managed with TEER. Of these, 176 were included in the analysis, 23 (13%) patients had acute papillary muscle rupture (PMR) and 153 (87%) acute secondary MR.

View Article and Find Full Text PDF

Analysis of the haemodynamic changes caused by surgical and transcatheter aortic valve replacements by means fluid-structure interaction simulations.

Comput Biol Med

January 2025

UCL Mechanical Engineering, University College London, UK; Ri.MED Foundation, Palermo, Italy; University of Palermo, Department of Engineering, Palermo, Italy. Electronic address:

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.

View Article and Find Full Text PDF

Background: The concomitant hiatal hernia repair with endoscopic fundoplication (c-TIF) is a novel anti-reflux procedure that addresses the hiatus and the gastro-esophageal flap valve for surgical candidates with GERD. We aim to compare the outcomes of a hiatal hernia repair with endoscopic fundoplication (TIF) vs surgical partial fundoplication (anterior and posterior) with regards to quality-of-life scores at 12 months after surgery.

Study Design: Following IRB approval, a prospectively maintained anti-reflux database was retrospectively reviewed to identify patients who underwent a c-TIF procedure or a surgical hiatal hernia repair with partial fundoplication.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!