A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel monohydrogenphosphate ion-selective polymeric membrane sensor based on phenyl urea substituted calix[4]arene. | LitMetric

Novel monohydrogenphosphate ion-selective polymeric membrane sensor based on phenyl urea substituted calix[4]arene.

Talanta

Department of Chemistry, School of Sciences, Gujarat University, Navrangpura, Ahmedabad 380009, Gujarat, India.

Published: October 2011

A highly selective and sensitive PVC membrane, containing phenylurea substituted calix[4]arene was found to be a suitable ionophore for monohydrogen phosphate (HPO(4)(2-)) ions that exhibited a Nernstian response (with a slope of -29.4 ± 0.3 mV decade(-1)). The working concentration range of the electrode was 6.0 × 10(-8)-1.0 × 10(-1) mol L(-1) with a detection limit of 2.0 × 10(-8) mol L(-1). The response time of the sensor in the whole concentration range is very short (<8s), with a considerable lifetime of at least 15 weeks. The sensor possesses the advantages of short response time, low detection limit and a high selectivity towards a large number of inorganic anions. The developed sensor was used as an indicator electrode in potentiometric titration of monohydrogen phosphate ion with barium chloride. The proposed sensor was successfully applied for the direct determination of monohydrogen phosphate in real life samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2011.08.042DOI Listing

Publication Analysis

Top Keywords

substituted calix[4]arene
8
concentration range
8
mol l-1
8
novel monohydrogenphosphate
4
monohydrogenphosphate ion-selective
4
ion-selective polymeric
4
polymeric membrane
4
membrane sensor
4
sensor based
4
based phenyl
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!