Biological effects and adaptive response from single and repeated computed tomography scans in reticulocytes and bone marrow of C57BL/6 mice.

Radiat Res

Department of Medical Physics and Applied Radiation Sciences, Nuclear Research Building Room 227, 1280 Main St. West, McMaster University, Hamilton, Ontario, Canada, L8S 4K1.

Published: February 2012

This study investigated the biological effects and adaptive responses induced by single and repeated in vivo computed tomography (CT) scans. We postulated that, through the induction of low-level oxidative stress, repeated low-dose CT scans (20 mGy, 2 days/week, 10 weeks) could protect mice (C57BL/6) from acute effects of high-dose radiation (1 Gy, 2 Gy). The micronucleated reticulocyte (MN-RET) count increased linearly after exposure to single CT scans of doses ranging from 20 to 80 mGy (P = 0.033). Ten weeks of repeated CT scans (total dose 400 mGy) produced a slight reduction in spontaneous MN-RET levels relative to levels in sham CT-scanned mice (P = 0.04). Decreases of nearly 10% in γ-H2AX fluorescence levels were observed in the repeated CT-scanned mice after an in vitro challenge dose of 1 Gy (P = 0.017) and 2 Gy (P = 0.026). Spontaneous apoptosis levels (caspase 3 and 7 activation) were also significantly lower in the repeated CT-scanned mice than the sham CT-scanned mice (P < 0.01). In contrast, mice receiving only a single CT scan showed a 19% elevation in apoptosis (P < 0.02) and a 10% increase in γ-H2AX fluorescence levels after a 2-Gy challenge (P < 0.05) relative to sham CT controls. Overall, repeated CT scans seemed to confer resistance to larger doses in mice, whereas mice exposed to single CT scans exhibited transient genotoxicity, enhanced apoptosis, and characteristics of radiation sensitization.

Download full-text PDF

Source
http://dx.doi.org/10.1667/rr2532.1DOI Listing

Publication Analysis

Top Keywords

ct-scanned mice
16
mice
9
biological effects
8
effects adaptive
8
single repeated
8
computed tomography
8
tomography scans
8
single scans
8
repeated scans
8
sham ct-scanned
8

Similar Publications

Craniofacial and dentoalveolar abnormalities are present in all types of osteogenesis imperfecta (OI). Mouse models of the disorder are critical to understand these abnormalities and underlying OI pathogenesis. Previous studies on severely affected OI mice report a broad spectrum of craniofacial phenotypes, exhibiting some similarities to the human disorder.

View Article and Find Full Text PDF

Morphometric studies of 3D micro CT-scanned images can provide insights into the evolution of the brain and sensory structures but such data are still scarce for the most diverse mammalian order of rodents. From reviewed and new data, we tested for convergence to extreme aridity and high elevation in the sensory and brain morphology of rodents, from morphometric data from micro-CT X-ray scans of 174 crania of 16 species of three distantly related African murid (soft-furred mice, Praomyini, laminate-toothed rats, Otomyini, and gerbils, Gerbillinae) clades and one North American cricetid (deer mice and white-footed mice, Peromyscus) clade. Recent studies demonstrated convergent evolution acting on the oval window area of the cochlea (enlarged in extremely arid-adapted species of Otomyini and Gerbillinae) and on endocranial volume (reduced in high elevation taxa of Otomyini and Peromyscus).

View Article and Find Full Text PDF

Trabecular bone is a spongy bone tissue that serves as a scaffolding-like support inside many skeletal elements. Previous research found allometric variation in some aspects of trabecular bone architecture (TBA) and bone microstructure, whereas others scale isometrically. However, most of these studies examined very wide size and phylogenetic ranges or focused exclusively on primates or lab mice.

View Article and Find Full Text PDF

Objectives: Computed tomography (CT) imaging is considered relatively safe and is often used in preclinical research to study physiological processes. However, the sum of low-dose radiation, anesthesia, and animal handling might impact animal welfare and physiological parameters. This is particularly relevant for longitudinal studies with repeated CT examinations.

View Article and Find Full Text PDF

Metastasis of cancer to the spine impacts bone quality. This study aims to characterize vertebral microdamage secondary to metastatic disease considering the pattern of damage and its relationship to stress and strain under load. Osteolytic and mixed osteolytic/osteoblastic vertebral metastases were produced in athymic rats via HeLa cervical or canine Ace-1 prostate cancer cell inoculation, respectively.

View Article and Find Full Text PDF