Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This overall study aims to investigate gradient elution ion-exchange chromatography of pharmaceutically relevant compounds using universal nebulisation detectors, such as evaporative light scattering detection (ELSD). Addition of organic solvents to the eluent is necessary to minimise hydrophobic adsorption on the polymeric stationary phase and improve solubility of analytes. It is also necessary to de-salt the eluent prior to detection, and in this work, ion chromatography suppressors were used for this step. Such suppressors have been designed for aqueous eluents, so the purpose of the present study was to investigate the effects of methanol and acetonitrile on suppressor performance. Chemical and electrolytic suppressors were evaluated for baseline drift, noise and efficiency of suppression using aqueous/organic eluents containing up to 40% (v/v) methanol or acetonitrile. Chemical suppression of aqueous/organic eluents showed minimal noise levels, uniform low baseline and low gradient drift. Electrolytic suppression gave good performance, but with higher baseline conductivity levels and baseline drift than chemical suppression. The elevated baseline was found not to be caused by incomplete suppression of the eluent, but was attributed to chemical reactions involving the organic solvents and facilitated by high electric currents and heat generation. It was demonstrated that suppressed ion-exchange separation using a complex KOH elution profile could be coupled with ELSD, with the suppressor effectively de-salting the eluent, producing a stable baseline. Finally, complementary separation selectivity was demonstrated using a set of pharmaceutically related organic acids separated by reversed-phase and ion-exchange methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2011.10.011 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!