Rationale And Objectives: To assess the effect of measurement time on blood flow (BF), blood volume (BV), and k-trans-values (flow extraction product) in patients undergoing volume perfusion computed tomography (VPCT) for lung cancer.

Materials And Methods: This prospective study was approved by our local Research Ethics Committee and informed consent was obtained in all patients. Between December 2009 and December 2010, 75 VPCT scans were obtained in 54 consecutive patients (15 women, 39 men) with histologically confirmed lung cancer. A 64-second VPCT of the tumor (80 kV, 60 mAs) using 128 × 0.6-mm collimation, 6.9-cm z-axis coverage and a total of 26 volume measurements, was performed. BF, BV, and K(trans) were determined. Data evaluation was performed for different measurement times (64 seconds, 45 seconds, 39 seconds, and 36 seconds) by removing the last two, four, and five scans and repeating the analysis. A one-way repeated-measures analysis of variance was used to test for effects of measurement time on BF, BV, and k-trans and unpaired/paired Student t-tests were applied for comparisons within/between groups, respectively.

Results: No effect of measurement time on BF values was noted (P > .05), whereas a significant decrease of BV values (at 39 seconds: 71% ± 2% of 64-second values) and a significant increase of k-trans-values (at 39 seconds: 146% ± 8% of 64-second values) were observed with progressively shortened measurement time (P < .05, respectively). Additionally, with reduced measurement time, the increase in k-trans-values was significantly more pronounced in those patient groups with higher BV (at 39 seconds: 171% ± 15% versus 120% ± 3% of 64-second measurements), and those with lower k-trans (at 39 seconds: 167% ± 16% versus 126% ± 4% of 64-second measurements) (P < .05, respectively).

Conclusion: Whereas estimation of BF in lung cancer was independent from VPCT measurement time within the chosen ranges, approximation of both BV and k-trans was affected by measurement duration. A fixed measurement time of 40 seconds is recommended.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2011.09.010DOI Listing

Publication Analysis

Top Keywords

measurement time
28
lung cancer
12
seconds seconds
12
measurement
9
seconds
9
flow extraction
8
extraction product
8
volume perfusion
8
64-second values
8
increase k-trans-values
8

Similar Publications

Aim: The aim of the study is to determine sac volume based on radiological examinations in patients undergoing surgery for myelomeningocele (MMC) and to investigate the relationship of sac volume with hydrocephalus and Chiari malformation type 2 (CM) with a view to determining the optimum length of follow-up and recommend a treatment plan.

Material And Methods: The present study involved the retrospective review of radiologic examinations and medical files of 81 patients who underwent surgery for myelomeningocele between 2015 and 2022 in the neurosurgery clinic of Ankara Training and Research Hospital. Then, MMC sac volumes were measured and the statistical relationship of these measurements with the Evans Index, progressive enlargement of the ventricles after sac repair and CM was investigated.

View Article and Find Full Text PDF

Aim: We investigated the short- term results of dynamic/semi-rigid stabilization in patients with cervi-cal spinal stenosis and compare them with patients for which decompression and posterior cer-vical fusion was performed.

Material And Methods: 28 patients were included in this study. Group 1 was the semi-rigid group (four male, ten fe-male), group 2 was the fusion group (nine male, five female).

View Article and Find Full Text PDF

Obesity significantly influences drug pharmacokinetics (PK), which challenges optimal dosing. This study examines the effects of diet-and-exercise-induced weight loss on key drug-metabolizing enzymes and gastric emptying in patients with obesity, who frequently require medications for comorbidities. Participants followed a structured weight management program promoting weight loss over 3-6 months and were not concomitantly on potential CYP inducers or inhibitors.

View Article and Find Full Text PDF

Drug-Drug Interaction Between Rifampicin and Albuvirtide: A Phase 1, Randomized, Open-Label Study.

J Clin Pharmacol

January 2025

Department of Pharmacy, Shanghai Public Health Clinical Center, Fudan University, Shanghai, China.

Albuvirtide (ABT) is a novel long-acting fusion inhibitor for human immunodeficiency virus type 1 (HIV-1), and may be co-administered with rifampicin (RIF) in patients concurrent with tubercle bacillus and HIV-1. This study was conducted to investigate the pharmacokinetic effect of co-administration of the two drugs. In the study, 24 healthy volunteers were randomized to receive ABT alone or with RIF.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the efficacy and safety of the Ahmed glaucoma valve in pediatric patients with refractory glaucoma.

Methods: A comprehensive literature search was conducted across multiple major databases, including PubMed, Embase, the Cochrane Library of Systematic Reviews, Science Direct, China's National Knowledge Infrastructure, and the Wanfang database. We retrieved studies published before December 2022 that met the inclusion criteria, including clinical controlled trials (randomized controlled trials) and clinical noncontrolled trials (non-randomized controlled trials) on the use of Ahmed glaucoma valve in pediatric patients with refractory glaucoma.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!