A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A compact diode laser cavity ring-down spectrometer for atmospheric measurements of NO3 and N2O5 with automated zeroing and calibration. | LitMetric

A compact rack-mounted cavity ring-down spectrometer (CRDS) for simultaneous measurements of the nocturnal nitrogen oxides NO(3) and N(2)O(5) in ambient air is described. The instrument uses a red diode laser to quantify mixing ratios of NO(3) (at its absorption maximum at 662 nm) and of N(2)O(5) following its thermal dissociation to NO(3) in a second detection channel. The spectrometer is equipped with an automated zeroing and calibration setup to determine effective NO(3) absorption cross-sections and NO(3) and N(2)O(5) inlet transmission efficiencies. The instrument response was calibrated using simultaneous measurements of NO(2), generated by thermal dissociation of N(2)O(5) and/or by titration of NO(3) with excess NO, using blue diode laser CRDS at 405 nm. When measuring ambient air, the (2σ, 10 s) precision of the red diode CRDS varied between 5 and 8 parts-per-trillion by volume (pptv), which sufficed to quantify N(2)O(5) concentrations under moderately polluted conditions. Sample N(2)O(5) measurements made on a rooftop on the University of Calgary campus in August 2010 are presented. A maximum N(2)O(5) mixing ratio of 130 pptv was observed, corresponding to a steady-state lifetime of less than 50 min. The NO(3) mixing ratios were below the detection limit, consistent with their predicted values based on equilibrium calculations. During the measurement period, the instrument response for N(2)O(5) was 70% of the theoretical maximum, rationalized by a slight mismatch of the laser diode output with the NO(3) absorption line and a N(2)O(5) inlet transmission efficiency less than unity. Advantages and limitations of the instrument's compact design are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1366/11-06384DOI Listing

Publication Analysis

Top Keywords

diode laser
12
no3 n2o5
12
no3 absorption
12
n2o5
10
no3
9
cavity ring-down
8
ring-down spectrometer
8
automated zeroing
8
zeroing calibration
8
simultaneous measurements
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!