Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A compact rack-mounted cavity ring-down spectrometer (CRDS) for simultaneous measurements of the nocturnal nitrogen oxides NO(3) and N(2)O(5) in ambient air is described. The instrument uses a red diode laser to quantify mixing ratios of NO(3) (at its absorption maximum at 662 nm) and of N(2)O(5) following its thermal dissociation to NO(3) in a second detection channel. The spectrometer is equipped with an automated zeroing and calibration setup to determine effective NO(3) absorption cross-sections and NO(3) and N(2)O(5) inlet transmission efficiencies. The instrument response was calibrated using simultaneous measurements of NO(2), generated by thermal dissociation of N(2)O(5) and/or by titration of NO(3) with excess NO, using blue diode laser CRDS at 405 nm. When measuring ambient air, the (2σ, 10 s) precision of the red diode CRDS varied between 5 and 8 parts-per-trillion by volume (pptv), which sufficed to quantify N(2)O(5) concentrations under moderately polluted conditions. Sample N(2)O(5) measurements made on a rooftop on the University of Calgary campus in August 2010 are presented. A maximum N(2)O(5) mixing ratio of 130 pptv was observed, corresponding to a steady-state lifetime of less than 50 min. The NO(3) mixing ratios were below the detection limit, consistent with their predicted values based on equilibrium calculations. During the measurement period, the instrument response for N(2)O(5) was 70% of the theoretical maximum, rationalized by a slight mismatch of the laser diode output with the NO(3) absorption line and a N(2)O(5) inlet transmission efficiency less than unity. Advantages and limitations of the instrument's compact design are discussed.