A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of tooth displacement between buccal mini-implants and palatal plate anchorage for molar distalization: a finite element study. | LitMetric

The purposes of this study were to mechanically evaluate distalization modalities through the application of skeletal anchorage using finite element analysis. Base models were constructed from commercial teeth models. A finite element model was created and three treatment modalities were modified to make 10 models. Modalities 1 and 2 placed mini-implants in the buccal side, and modality 3 placed a plate on the palatal side. Distalization with the palatal plate in modality 3 showed bodily molar movement and insignificant displacement of the incisors. Placing mini-implants on the buccal side in modalities 1 and 2 caused the first molar to be distally tipped and extruded, while the incisors were labially flared and intruded. Distalization with the palatal plate rather than mini-implants on the buccal side provided bodily molar movement without tipping or extrusion. It is recommended to use our findings as a clinical guide for the application of skeletal anchorage devices for molar distalization.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejo/cjr130DOI Listing

Publication Analysis

Top Keywords

palatal plate
12
finite element
12
mini-implants buccal
12
buccal side
12
molar distalization
8
application skeletal
8
skeletal anchorage
8
distalization palatal
8
bodily molar
8
molar movement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!